Release Notes NET 13.2

Summary

With the new NET 13.2 version, NET Design users now have access to the Infas 360 data importer. This importer can be used to retrieve address data from infas360. This data import is subject to a charge. Please contact the sales department for a quote.

In addition, the new version also supports the current version of atesio Strategic, namely version 2022.

ATTENTION: The behavior of the "Assign duct to other segments/ducts" workflow has changed: Ducts are now no longer detached from the current segment or duct when they are assigned to another duct. An additional work step is required for this if the duct is to be "moved".

A bug in the GIS-NB integration in NET Engineering has been fixed. The check as to whether pipes need to be separated at the transition from protective pipes to route laying has been significantly improved and now only strikes if it is really necessary. This check is now only active for GIS-NB versions 3.1 and 3.2 and for trade call 1.0. If the installation depth in the protective pipe and in the route is identical, separation is also not necessary.

There is an extension for the DocPack that makes it possible to automatically link the documents created there to the respective data record via the document management. In combination with the function for uploading data from the document management system to NET Cloud, the documentation for a project can be made available in NET Cloud in just a few steps.

In addition, numerous minor adjustments and bug fixes have been made to further improve the quality and stability of the software solution.

Supported Software

  • Autodesk AutoCAD Map 3D

    • Autodesk AutoCAD Map 3D 2022.0.1 - Autodesk AutoCAD 2022.1.3 or later

    • Autodesk AutoCAD Map 3D 2023.0.2 - Autodesk AutoCAD 2023.1.1 or later

    • Autodesk AutoCAD Map 3D 2024.0.1 - Autodesk AutoCAD 2024.1 or later

  • TKI PostgreSQL Provider 4.1.0

  • Comsof Fiber Designer 2019.2.2 - Comsof Fiber Designer 22.2

  • Comsof Fiber 23.1 - Comsof Fiber 23.2

  • TKI Licensing 13.0
    (Only required for a manual installation on the network license server)

Release NET 13.2 in Detail

General

  • Document upload to NET cloud is successfully carried out without any errors

Dialogs

  • The error in the display of domain tables has been fixed.

Documentation Pack

  • The DocPack output now displays the elements to be output in alphabetical order.

  • The DocPack output now detects and corrects invalid folder structures for subfolders.

  • Opening a template in the DocPack configurator has been noticeably accelerated if several sub templates reference the same layout file.

  • A new database view for plots has been added.

  • The DocPack has been expanded to include a new function that makes it possible to link generated documents with the document management. Whether this functionality should be used can be specified using an option in the DocPack Output.

NET Design

  • There is now a new importer "Import from Infas geodata" which can be used to import demand points to NET Design. Please get in touch with our sales team for more information.

  • Before values are transferred from NET Design to NET Field Survey or vice versa, a validation takes place to check whether the length of the value in the source is greater than the maximum capacity of the field in the target data model. A corresponding message is then displayed to indicate whether the transfer was successful or not. If the transfer was not successful, a message is displayed indicating the cause and the source of the problem.

Dialogs

  • Length attributes in the dialog are now by default limited to two decimal places.

atesio Integration

  • As soon as the user clicks on the "Cancel" button, the button is deactivated and the process is canceled. No stack trace, error reports etc. are displayed in the log.

Comsof Fiber Integration

  • Changed to the attribute "duct type restriction" are now correctly detected and reset the area preparation data. This allows the changed to take effect during the next calculation without manually resetting the area preparation data.

NET Engineering

  • Connection overview: Duct insertions and fittings are not shows as either start- or endpoint.

  • The list of start- and endpoints in the connection overview is now being sorted.

  • All map views of the datamodels NET Engineering Base, Duct, FO and TP now contain the fields date_created, date_modified, user_created and user_modified from the corresponding attribute class.

  • The report "segment costs" has been corrected.

  • A name scheme has been corrected so that it is now valid and can be used.

  • The FO Connector type "LC/APC" is now automatically created with Angled polish = "Yes". In existing databases, the value is corrected if Angled polish = "No" is stored.

  • Fixed a bug that caused a fitting to not be recognized and displayed in the duct connection editor if the start or end point of its connected ducts match the start point of the duct connection editor, but the fitting's geometry is located somewhere else. In addition, such a fitting is now correctly recognized and displayed in the duct connection editor when opened through the fitting's form.

Workflows

  • The functions "Assign duct to further segments", "Assign duct to further segments/ducts", "Assign existing ducts", "Assign cable to further segments", "Assign cable to further segments/ducts", "Assign existing cables" and "Edit segment und duct assignments" have been fundamentally revised and standardized.

  • If the "Assign existing ducts" or "Assign existing cables" functions would result in incorrect geometry due to the assignment, there is now a query asking whether this action should still be executed or canceled. In addition, an option in this query window can be used to select whether this query should be displayed again within the current session or until the project is closed.

  • The display of the light/dark colour scheme and scaling of the "Create duct template" workflow has been optimized.

  • The functions "Assign duct to further segments" and "Assign cable to further segments" now display a meaningful error message if the assignment would result in an invalid geometry.

Dialogs

  • If the "Remove geometry of all child cables" function is canceled, an error no longer occurs.

  • In several forms, the info fields have been optimized with regard to maximum number of characters, field height, line breaks and word wraps.

  • The correct Splitter is now displayed again behind the Splitter paths in the "FO Splice" form.

  • The functions for selecting and filtering the Duct template have been improved in the "Duct type" and "Duct" forms.

  • There are now two new buttons in the "FO Terminator", "FO Closure", "TP Terminator" and "TP Closure" forms, which display all incoming and outgoing cables for all data records in the filter.

Reports

  • The length of a cable section is now displayed in the splice plan from tracing.

  • Duct Tap: The report "duct connections" shows the colors of all ducts correctly once again.

  • Work order: The handling of line breaks in the report has been improved.

  • If an attempt was made to call up a report without a data record being selected, an error occurred. This behaviour has been corrected and a message is now displayed stating that the report is empty.

GIS-Nebenbestimmungen

  • Output of the state in empty ducts works again for all versions.

  • The installation depth check has been removed for non-relevant versions.

  • The obsolete designation "BMVI" has been removed and replaced by GIS-NB.

TNIM

  • The TNIM import now also accepts unpacked files with the extension ".tnim".

  • The default source in TNIM v2.1 for SQLite projects was previously called "Default", now the name of the project is used instead.

  • The TNIM key and TNIM source fields are now editable in all forms.

Redlining

  • When transferring data from Redlining to NET Engineering, an incorrect behavior was corrected in the "Link fiber connections" action, which meant that the action could not be completed.

  • There is a new validation, which checks if there are any objects without geometry.

  • A new function was added to the redlining dialogs. This allows navigating from the redlining objects to the assigned service positions.

  • When transferring data from Redlining to NET Engineering, the performance of the "Link distribution network" action has been significantly improved.

  • Removed the FID_PARENT attribute from redlining fittings - as a result, a validation that checked if a redlining segment had enough fittings was also removed.

  • The help link in the Redlining forms of the each individual object classes now leads to the appropriate pages in the online help.

  • When transferring the redlining data to NET Engineering, not only the segments but also the fittings and structures are now moved during the "Snap redlining features" action.

NET Build Integration

  • When synchronizing field reports from NET Build, clusters are now also transferred.

  • When transferring data from NET Build to NET Engineering (redlining), an error report occurred if the configuration for the transfer was not available. This error has been fixed.

  • Data transfer from NET Build Push to Redlining is not supported with the IMBatch.

  • When synchronizing field reports from NET Build, only service items and materials with quantity greater than 0 are now transferred.

  • When transferring data from NET Build to the redlining data model, an error occurred if the abbreviation of the building was more than 4 characters long. This error has been fixed.

  • When transferring data from NET Engineering to NET Build, it is now possible to select status values for the objects to be transferred.

  • When transferring data from NET Engineering to NET Build, the "status" of the planning objects is now also transferred.

  • For the validation window of the data transfer from NET Engineering to NET Build, improvements have been made to the display of texts.

  • A new validation "Segments with invalid geometry" has been added for data transfer to NET Build. This checks whether there are segments with invalid geometry that are to be transferred to NET Build. A validation message is displayed for each affected segment.

  • A new validation has been added to the data transfer to NET Build, which checks whether an attempt is made to transfer duct bundles or single ducts without names.

  • A new validation "Empty Segments" has been added for data transfer to NET Build. This checks whether there are segments without pipes or cables that are to be transferred to NET Build. A validation message is displayed for all segments found.

  • When using the NET Build Push, a new option has been added to the creation of the new region. This option determines whether the new region should only be visible in the selected segment.

  • Before data is transferred from NET Build, the system first checks whether all the necessary settings are available in NET Build.

NET Field Survey

Dialogs

  • Length attributes in dialogs are now shown with two decimal places by default.

Validation

  • The validation for "Cabinets or Address Points in multiple parent Clusters" now only refers to standard clusters.

  • The validation for "Cabinets or Address Points in multiple parent Clusters" now ignores elements that are not included.

Changes to the Data Model since NET 13.0

NET Design

Base Data Model

13.1

  • Added additional target tables in FID_FEATURE to the table TC_PL_ATTR_VALUE.

    • TC_PL_BOUNDARY.FID

    • TC_PL_PARCEL.FID

    • TC_PL_ROLLOUT_AREA.FID

    • TC_PL_SUBAREA.FID

13.2

  • No changes to the data model - Structural update only for new forms and reports

GIS-Nebenbestimmungen Data Model

13.1

  • Removed "BMVI" from all captions.

  • Added new column BMVI_IS_TECH in TC_PL_DEMAND_POINT with relation to TC_PL_BMVI_TECH_IS_TBD.

  • Added new column BMVI_PLAN_AUSB in TC_PL_DEMAND_POINT with relation to TC_PL_BMVI_PLAN_AUSB_TBD.

  • Added new column BMVI_TECH_1_YEAR_INT in TC_PL_DEMAND_POINT with relation to TC_PL_BMVI_TECH_IS_TBD.

  • Added new column BMVI_TECH_3_YEAR_INT in TC_PL_DEMAND_POINT with relation to TC_PL_BMVI_TECH_IS_TBD.

  • Added new domain table TC_PL_BMVI_PLAN_AUSB_TBD.

    • 3 - Pre-marketing is carried out

  • Added new domain table TC_PL_BMVI_TECH_IS_TBD.

    • 1 - FTTB/H

    • 2 - HFC

    • 8 - Other Technology

13.2

  • The captions of a few remaining identifiers have been changed from “BMVI” to “GIS-NB”. There are not structural changes.

NET Engineering

Base Data Model

13.1

  • No changes to the data model - Structural update only for new forms and reports

13.2

  • The size of the column INFO in the Action area (TC_ACTION_AREA) feature class has been increased to 255 characters.

  • The columns DATE_CREATED, DATE_MODIFIED, USER_CREATED and USER_MODIFIED were added to the following views:

    • TC_M_BUILDING

    • TC_M_CLUSTER_STATISTIC

    • TC_M_SP_CABINET

    • TC_M_SP_MANHOLE

    • TC_M_SP_MARKER

    • TC_M_SP_POLE

    • TC_M_SP_SEGMENT

    • TC_M_SWITCHING_POINT

  • The backing table for the color table (TC_COLOR) was updated.

    • The column AutoCAD index (ACAD_INDEX) is not optional anymore and got the default value 0

    • The column blue value (B_VALUE) is not optional anymore and got the default value 0

    • The column dashed (DASHED) is not optional anymore and got the default value 0

    • The column green value (G_VALUE) is not optional anymore and got the default value 0

    • The column position(ORDER_ID) is not optional anymore and got the default value 0

    • The column red value (R_VALUE) is not optional anymore and got the default value 0

Duct Data Model

13.1

  • No changes to the data model - Structural update only for new forms and reports

13.2

  • The columns DATE_CREATED, DATE_MODIFIED, USER_CREATED and USER_MODIFIED were added to the following views:

    • TC_M_CS_CABLE

    • TC_M_CS_DUCT

    • TC_M_SP_DUCT

    • TC_M_SP_DUCT_INSERTION

    • TC_M_SP_DUCT_TAP

    • TC_M_SP_FITTING

  • The field LENGTH got added to the view TC_REP_SEGMENTCOSTS, in case it was not present already.

Fiber Optic Data Model

13.1

  • No changes to the data model - Structural update only for new forms and reports

  • The columns DATE_CREATED, DATE_MODIFIED, USER_CREATED and USER_MODIFIED were added to the following views:

    • TC_M_FO_CABLE

    • TC_M_FO_CLOSURE

    • TC_M_FO_TERMINATOR

    • TC_M_FO_SP_ASSIGNMENTS

  • The text format of the output of the following views as fixed. There are no structure changes.

    • TC_REP_WO_FO_PATCH

    • TC_REP_WO_FO_SPLICE

  • The size of the column INFO in cable loop (TC_FO_CABLE_LOOP) feature classes got increased to 255 characters

Telephony Data Model

13.1

  • No changes to the data model - Structural update only for new forms and reports

13.2

  • The columns DATE_CREATED, DATE_MODIFIED, USER_CREATED and USER_MODIFIED were added to the following views:

    • TC_M_TP_CABLE

    • TC_M_TP_CLOSURE

    • TC_M_TP_TERMINATOR

    • TC_M_TP_SP_ASSIGNMENTS

  • The text format of the output of the following views as fixed. There are no structure changes.

    • TC_REP_WO_TP_PATCH

    • TC_REP_WO_TP_SPLICE

GIS-Nebenbestimmungen Data Model

13.1

  • Added new column BMVI_IS_TECH in TC_TG_BUILDING with relation to TC_BMVI_TECH_IS_TBD.ID.

  • Added new column BMVI_PLAN_AUSB in TC_TG_BUILDING with relation to TC_BMVI_PLAN_AUSB_TBD.ID.

  • Added new column BMVI_TECH_1_YEAR_INT in TC_TG_BUILDING with relation to TC_BMVI_TECH_IS_TBD.ID.

  • Added new column BMVI_TECH_3_YEAR_INT in TC_TG_BUILDING with relation to TC_BMVI_TECH_IS_TBD.ID.

  • Added new domain table TC_BMVI_PLAN_AUSB_TBD.

    • 3 - Pre-marketing is carried out

  • Added new domain table TC_BMVI_TECH_IS_TBD.

    • 1 - FTTB/H

    • 2 - HFC

    • 8 - Other Technology

13.2

  • The captions of a few remaining identifiers have been changed from “BMVI” to “GIS-NB”. There are not structural changes.

Redlining Data Model

13.1

  • Added new column FID_STRUCTURE in TC_RL_CLOSURE with relation to TC_RL_STRUCTURE.FID.

  • Additional target table for the relation from TC_RL_MEASUREMENT_POINT.FID_FEATURE to TC_TG_BUILDING.FID.

  • Added new object class TC_RL_MEASUREMENT_L_MODEL.

  • Added new column FID_MODEL in TC_RL_MEASUREMENT_LINE with relation to TC_RL_MEASUREMENT_L_MODEL.FID.

  • Removed column ID_TYPE from TC_RL_MEASUREMENT_LINE.

  • Adjusted the view TC_M_RL_MEASUREMENT_LINE to use FID_MODEL instead of ID_TYPE.

  • Removed domain table TC_RL_MEASUREMENT_L_TYPE_TBD.

  • Added new object class TC_RL_MEASUREMENT_P_MODEL.

  • Added new column FID_MODEL in TC_RL_MEASUREMENT_POINT with relation to TC_RL_MEASUREMENT_P_MODEL.FID.

  • Removed column ID_TYPE from TC_RL_MEASUREMENT_POINT.

  • Adjusted the view TC_M_RL_MEASUREMENT_POINT to use FID_MODEL instead of ID_TYPE.

  • Removed domain table TC_RL_MEASUREMENT_P_TYPE_TBD.

13.2

  • The column FID_PARENT was removed from the Redlining Fitting (TC_RL_FITTING)

  • The German caption of the column CONSTRUCTION_TYPE in Redlining Trasse (TC_RL_SEGMENT) got changed.

NET Field Survey

GIS-Nebenbestimmungen Data Model

13.2

  • The captions of a few remaining identifiers have been changed from “BMVI” to “GIS-NB”. There are not structural changes.

DocPack

13.2

  • A new view for the plot sequences has been added (TC_V_PLOT_SEQUENCE)

Changes to the dialogs since NET 13.0

NET Design

Base Data Model

13.1

  • New dialog for Boundary (TC_PL_BOUNDARY): Attribute Value (TC_PL_ATTR_VALUE)

  • New dialog for Parcel (TC_PL_PARCEL): Attribute Value (TC_PL_ATTR_VALUE)

  • New dialog for Rollout Area (TC_PL_ROLLOUT_AREA): Attribute Value (TC_PL_ATTR_VALUE)

  • New dialog for Subarea (TC_PL_SUBAREA): Attribute Value (TC_PL_ATTR_VALUE)

  • New references from Cable Type (TC_PL_CABLE_TYPE.FID)

    • to Building (TC_PL_BUILDING.FID_FORCED_CABLE_TYPE)

    • to Demand Point (TC_PL_DEMAND_POINT.FID_FORCED_CABLE_TYPE)

13.2

  • The number of decimal places for the display has been set to 2.

    • Boundary (TC_PL_BOUNDARY) - Length in m (LENGTH)

    • Boundary (TC_PL_BOUNDARY) - Width (WIDTH)

    • Building → Number of residents (TC_PL_RESIDENT) - Adoption rate (ADOPTION_RATE)

    • Building → Number of residents (TC_PL_RESIDENT) - Expected revenue (EXPECTED_REVENUE)

    • Demand Point → Number of residents (TC_PL_RESIDENT) - Adoption rate (ADOPTION_RATE)

    • Demand Point → Number of residents (TC_PL_RESIDENT) - Expected revenue (EXPECTED_REVENUE)

    • Number of residents (TC_PL_RESIDENT) - Adoption rate (ADOPTION_RATE)

    • Number of residents (TC_PL_RESIDENT) - Expected revenue (EXPECTED_REVENUE)

    • Result Kabelloop (TC_PL_OUT_CABLE_LOOP) - Length (LENGTH)

GIS-Specifications Data Model

13.1

  • Dialog for Demand Point (TC_PL_DEMAND_POINT):

    • Changed control for "Technology within one year" from text field to dropdown. Database field changed from BMVI_TECH_1_YEAR to BMVI_TECH_1_YEAR_INT.

    • Changed control for "Technology within three years" from text field to dropdown. Database field changed from BMVI_TECH_3_YEAR to BMVI_TECH_3_YEAR_INT.

    • Changed control for "Technology Is Supply" from text field to dropdown. Database field changed from BMVI_TECH_IS to BMVI_IS_TECH.

    • Added new dropdown "Expansion Plan" (BMVI_PLAN_AUSB)

13.2

  • The caption “BMVI” has been replaced by “GIS-NB” in the following dialogs:

    • Cable (TC_PL_CABLE)

    • Duct (TC_PL_DUCT)

    • Expansion area (TC_PL_EXPANSION_AREA)

    • Layer Point (TC_PL_LAYER_POINT)

    • Market survey (TC_PL_MARKET_SURVEY)

    • Possible trench (TC_PL_POSSIBLE_TRENCH)

    • Structure (TC_PL_STRUCTURE)

  • Controls related to GIS-NB have been moved to the GIS-NB tab.

    • Expansion area (TC_PL_EXPANSION_AREA)

    • Foreign area (TC_PL_FOREIGN_AREA)

    • Political area (TC_PL_POLITICAL_AREA)

    • White spot (TC_PL_WHITE_SPOT)

  • The number of decimal places for the display has been set to 2.

    • Expansion area (TC_PL_EXPANSION_AREA) - Area (AREA)

    • Foreign area (TC_PL_FOREIGN_AREA) - Area (AREA)

    • Market survey (TC_PL_MARKET_SURVEY) - Area (AREA)

    • Political area (TC_PL_POLITICAL_AREA) - Area (AREA)

    • White spot (TC_PL_WHITE_SPOT) - Area (AREA)

NET Engineering

Base Data Model

13.2

  • The number of decimal places for the display has been set to 2.

    • Action Area (TC_ACTION_AREA) - Area (AREA)

    • Action Area Label (TC_ACTION_AREA_TBL) - Orientation (ORIENTATION)

    • Cluster Grid (TC_CLUSTER_GRID) - Area (AREA)

    • Cabinet Label (TC_SP_CABINET_TBL) - Orientation (ORIENTATION)

    • Manhole Label (TC_SP_MANHOLE_TBL) - Orientation (ORIENTATION)

    • Survey Plan Point (TC_SP_POINT) - Orientation (ORIENTATION)

    • Pole Label (TC_SP_POLE_TBL) - Orientation (ORIENTATION)

    • Segment Label (TC_SP_SEGMENT_TBL) - Orientation (ORIENTATION)

    • Switching Point Label (TC_SP_SWITCHING_POINT_TBL) - Orientation (ORIENTATION)

    • Building Label (TC_TG_BUILDING_TBL) - Orientation (ORIENTATION)

    • Topography point (TC_TG_POINT) - Orientation (ORIENTATION)

    • Topography cluster (TC_TG_POLYGON) - Area (AREA)

    • Street Label (TC_TG_STREET_TBL) - Orientation (ORIENTATION)

  • All Info fields (INFO) have been set to have the height of 51, to support multiple lines and automatically apply line breaks. Changes were done in the following dialogs:

    • Action area (TC_ACTION_AREA)

    • Element library (TC_ELEMENT_LIBRARY)

    • Line (TC_LINE)

    • Point (TC_POINT)

    • Drilling rig (TC_SP_DRILLING_RIG)

    • Marker (TC_SP_MARKER)

    • Marker model (TC_SP_MARKER_MODEL)

    • Patch panel (TC_SP_PATCH_PANEL)

    • Patch panel model (TC_SP_PATCH_PANEL_MODEL)

    • Rack panel (TC_SP_RACK_PANEL)

    • Rack panel model (TC_SP_RACK_PANEL_MODEL)

    • Status (TC_STATUS)

    • Switching point model (TC_SWITCHING_POINT_MODEL)

    • Topography point (TC_TG_POINT)

    • Topography cluster (TC_TG_POLYGON)

Duct Data Model

13.2

  • The number of decimal places for the display has been set to 2.

    • Duct insertion label (TC_SP_DUCT_INSERTION_TBL) - Orientation (ORIENTATION)

    • Duct tap line (TC_SP_DUCT_TAP_LINE) - Length (LENGTH)

    • Duct tap line label (TC_SP_DUCT_TAP_LINE_TBL) - Orientation (ORIENTATION)

    • Duct tap label (TC_SP_DUCT_TAP_TBL) - Orientation (ORIENTATION)

    • Duct label (TC_SP_DUCT_TBL) - Orientation (ORIENTATION)

    • Duct (TC_SP_FITTING_TBL) - Orientation (ORIENTATION)

  • All Info fields (INFO) have been set to have the height of 51, to support multiple lines and automatically apply line breaks. Changes were done in the following dialogs:

    • Duct tap model (TC_SP_DUCT_TAP_MODEL)

Fiber Optic Data Model

13.1

  • Dialog for Fiber Optic Splice (TC_FO_SPLICE):

    • New named filters:

      • Show splices

      • Show stored fibers

      • Show uncut fibers in BA

      • Show uncut fibers

    • New SQL Label "Splice Type" ($SQLLABELSPLICETYPE)

    • Corrected positioning of Document Management ($DOCUMENTMANAGER)

13.2

  • The number of decimal places for the display has been set to 2.

    • FO cable loop label (TC_FO_CABLE_LOOP_TBL) - Orientation (ORIENTATION)

    • FO cable model (TC_FO_CABLE_MODEL) - Diameter (DIAMETER)

    • FO connector label (TC_FO_CONNECTOR_TBL) - Orientation (ORIENTATION)

    • FO fiber label (TC_FO_FIBER_TBL) - Orientation (ORIENTATION)

    • FO patch data (TC_FO_PATCH_DATA) - Attenuation (ATTENUATION)

    • FO patch fiber label (TC_FO_PATCH_FIBER_TBL) - Orientation (ORIENTATION)

    • FO patch label (TC_FO_PATCH_TBL) - Orientation (ORIENTATION)

    • FO splice graphics label (TC_FO_SPLICE_GRAPHICS_TBL) - Orientation (ORIENTATION)

    • FO splice label (TC_FO_SPLICE_TBL) - Orientation (ORIENTATION)

    • FO splitter path label (TC_FO_SPLITTER_PATH_TBL) - Orientation (ORIENTATION)

    • FO splitter label (TC_FO_SPLITTER_TBL) - Orientation (ORIENTATION)

    • FO terminator label (TC_FO_TERMINATOR_TBL) - Orientation (ORIENTATION)

  • All Info fields (INFO) have been set to have the height of 51, to support multiple lines and automatically apply line breaks. Changes were done in the following dialogs:

    • FO cable loop (TC_FO_CABLE_LOOP)

    • FO closure model (TC_FO_CLOSURE_MODEL)

  • New API controls have been added to the FO closure (TC_FO_CLOSURE) and the FO terminator (TC_FO_TERMINATOR)

    • $ENDINGLINECOMPLEX

    • $STARTINGLINECOMPLEX

  • Dialog FO splice (TC_FO_SPLICE) - The display for the connected splitters got corrected. The queries of the controls $SQLLABELSPLITTER1 and $SQLLABELSPLITTER2 got fixed.

Telephony Data Model

13.2

  • The number of decimal places for the display has been set to 2.

    • Telephony cable loop (TC_TP_CABLE_LOOP) - Orientation (ORIENTATION)

    • Telephony cable model (TC_TP_CABLE_MODEL) - Diameter (DIAMETER)

    • Telephony cable label (TC_TP_CABLE_TBL) - Orientation (ORIENTATION)

    • Telephony closure label (TC_TP_CLOSURE_TBL) - Orientation (ORIENTATION)

    • Telephony patch data (TC_TP_PATCH_DATA) - Attenuation (ATTENUATION)

    • Telephony patch label (TC_TP_PATCH_TBL) - Orientation (ORIENTATION)

    • Telephony pin data (TC_TP_PIN_DATA) - Attenuation (ATTENUATION)

    • Telephony splice data (TC_TP_SPLICE_DATA) - Attenuation (ATTENUATION)

    • Telephony splice graphics label (TC_TP_SPLICE_GRAPHICS_TBL) - Orientation (ORIENTATION)

    • Telephony terminator label (TC_TP_TERMINATOR_TBL) - Orientation (ORIENTATION)

    • Telephony wire data (TC_TP_WIRE_DATA) - Attenuation (ATTENUATION)

  • New API controls have been added to the Telephony closure (TC_TP_CLOSURE) and the Telephony terminator (TC_TP_TERMINATOR)

    • $ENDINGLINECOMPLEX

    • $STARTINGLINECOMPLEX

Redlining Data Model

13.1

  • Dialog for Redlining Closure (TC_PL_CLOSURE):

    • New reference field for Redlining Structure (FID_STRUCTURE)

    • Corrected positioning of Redlining Source Object (SOURCE_OBJECT)

  • Dialog for Measurement Line (TC_RL_MEASUREMENT_LINE):

    • Replaced reference to type ID_TYPE with FID_MODEL

    • Corrected positioning of all controls

  • New dialog for Measurement Line Model (TC_RL_MEASUREMENT_L_MODEL)

  • Dialog for Measurement Point (TC_RL_MEASUREMENT_POINT):

    • Extended target tables for parent object (FID_PARENT) to include Building (TC_TG_BUILDING)

    • Replaced reference to type ID_TYPE with FID_MODEL

    • Corrected positioning of all controls

  • New dialog for Measurement Point Model (TC_RL_MEASUREMENT_P_MODEL)

  • Corrected positioning of Source Object (SOURCE_OBJECT) in Redlining Segment (TC_RL_SEGMENT)

  • Corrected positioning of Source Object (SOURCE_OBJECT) in Redlining Structure (TC_RL_STRUCTURE)

  • Corrected positioning of Source Object (SOURCE_OBJECT) in Redlining Terminator (TC_RL_TERMINATOR)

13.2

  • The links to the online help got updated in the following dialogs

    • Redlining attribute (TC_RL_ATTRIBUTE)

    • Redlining cable (TC_RL_CABLE)

    • Redlining closure (TC_RL_CLOSURE)

    • Redlining connection (TC_RL_CONNECTION)

    • Redlining duct (TC_RL_DUCT)

    • Redlining fitting (TC_RL_FITTING)

    • Redlining measurement (TC_RL_MEASUREMENT)

    • Redlining measurement line (TC_RL_MEASUREMENT_LINE)

    • Redlining measurement point (TC_RL_MEASUREMENT_POINT)

    • Redlining segment (TC_RL_SEGMENT)

    • Redlining service item (TC_RL_SERVICE_ITEM)

    • Redlining structure (TC_RL_STRUCTURE)

    • Redlining terminator (TC_RL_TERMINATOR)

  • A new reference to the Redlining service item ($REF_TC_RL_SERVICE_ITEM) has been added to the following dialogs:

    • Redlining closure (TC_RL_CLOSURE)

    • Redlining fitting (TC_RL_FITTING)

    • Redlining segment (TC_RL_SEGMENT)

    • Redlining structure (TC_RL_STRUCTURE)

    • Redlining terminator (TC_RL_TERMINATOR)

  • The reference to the Redlining fitting ($REF_TC_RL_FITTING) has been removed from the dialog Redlining duct (TC_RL_DUCT)

  • The reference to the Redlining fitting ($REF_TC_RL_FITTING) has been removed from the dialog Redlining segment (TC_RL_SEGMENT)

  • The reference to the parent object (FID_PARENT) has been removed from the dialog for the Redlining fitting (TC_RL_FITTING)

GIS-Specifications Data Model

13.1

  • Dialog for Building (TC_TG_BUILDING):

    • Changed control for "Technology within one year" from text field to dropdown. Database field changed from BMVI_TECH_1_YEAR to BMVI_TECH_1_YEAR_INT.

    • Changed control for "Technology within three years" from text field to dropdown. Database field changed from BMVI_TECH_3_YEAR to BMVI_TECH_3_YEAR_INT.

    • Changed control for "Technology Is Supply" from text field to dropdown. Database field changed from BMVI_TECH_IS to BMVI_IS_TECH.

    • Added new dropdown "Expansion Plan" (BMVI_PLAN_AUSB)

13.2

  • The number of decimal places for the display has been set to 2.

    • Expansion area (TC_BMVI_EXPANSION_AREA) - Area (AREA)

    • Foreign area (TC_BMVI_FOREIGN_AREA) - Area (AREA)

    • Market survey (TC_BMVI_MARKET_SURVEY) - Area (AREA)

    • Political area (TC_BMVI_POLITICAL_AREA) - Area (AREA)

    • Supply area (TC_BMVI_SUPPLY_AREA) - Area (AREA)

    • White spot (TC_BMVI_WHITE_SPOT) - Area (AREA)

    • Building (TC_TG_BUILDING) - Loss (BMVI_LOSS)

Changes of the reports since NET 13.0

NET Engineering

Base Data Model

13.1

  • Support function to identify the location of images was updated in all reports.

13.2

  • The base filter of the reports were changed, to prevent an error showing up in case there are no rows selected in the corresponding dialog.

    • NET network overview service (NET Network Overview Service)

    • NET network overview service (just points) (NET Network Overview of Service(just Points))

    • NET point table (NET Point Table)

    • NET reports (NET Reports)

    • NET segment cost (NET Segment Cost)

    • NET work order (NET Work Order)

  • Replaced automatic line break with with manual line break in the report NET work order (NET Work Order).

Duct Data Model

13.1

  • The vertical text alignment has been fixed in the columns for the start and end node in the “duct tap connections” report.

  • Support function to identify the location of images was updated in all reports.

13.2

  • The base filter of the reports were changed, to prevent an error showing up in case there are no rows selected in the corresponding dialog.

    • NET duct end overview (Duct End Overview)

  • NET duct tap label (NET Duct Tap Label) - color 2 of the duct on the right side fixed

Fiber Optic Data Model

13.1

  • Support function to identify the location of images was updated in all reports.

13.2

  • The base filter of the reports were changed, to prevent an error showing up in case there are no rows selected in the corresponding dialog.

    • NET cable cost (NET Cable Cost)

    • NET FO cable section brief overview (NET FO Cable Section Brief Overview)

    • NET FO cable section service customer (NET FO Cable Section Service Customer)

    • NET FO cable section without trunk (NET FO Cable Section Without Trunk)

    • NET FO cable section (NET FO Cable Section)

    • NET FO cable trunk duct route (NET FO Cable Trunk Duct Route)

    • NET FO closure trays (NET FO Closure Trays)

    • NET FO connector used at switching point (NET FO Connector Used at Switching Point)

    • NET FO connector used at terminator (NET FO Connector Used at Terminator)

    • NET FO connector used with service at switching point (NET FO Connector Used with Service at Switching Point)

    • NET FO connector used with service at terminator (NET FO Connector Used with Service at Terminator)

    • NET FO connector at switching point (NET FO Connector at Switching Point)

    • NET FO connector at terminator (NET FO Connector at Terminator)

    • NET FO patch overview from connectors (NET FO Patch Overview from Connectors)

    • NET FO patches in switching point (NET FO Patches in Switching Point)

    • NET FO patches in terminator (NET FO Patches in Terminator)

    • NET FO terminator overview (NET FO Terminator Overview)

Telephony Data Model

13.1

  • Support function to identify the location of images was updated in all reports.

13.2

  • The base filter of the reports were changed, to prevent an error showing up in case there are no rows selected in the corresponding dialog.

    • NET Telephony cable section brief overview (NET TP Cable Section Brief Overview)

    • NET Telephony cable section service customer (NET TP Cable Section Service Customer)

    • NET Telephony cable section without trunk (NET TP Cable Section without Trunk)

    • NET Telephony cable section (NET TP Cable Section)

    • NET Telephony cable trunk duct route (NET TP Cable Trunk Duct Route)

    • NET Telephony network overview template (NET TP Network Overview Template)

    • NET Telephony patches in switching point (NET TP Patches in Switching point)

    • NET Telephony patches in terminator (NET TP Patches in Terminator)

    • NET Telephony pins in switching point (NET TP Pins in Switching point)

    • NET Telephony pins in terminator (NET TP Pins in Terminator)

    • NET Telephony splice overview closure (NET TP Splice Overview Closure)

    • NET Telephony splice overview terminator (NET TP Splice Overview Terminator)