Summary
This version is a unplanned release to fix a critical error in the Comsof Fiber integration. This error first appeared in NET 14.0.
The error caused crashes when reading data back from Comsof Fiber.
Aside from this error correction, this version is identical to NET 14.0.1.
Supported Software
-
Autodesk AutoCAD Map 3D
-
Autodesk AutoCAD Map 3D 2023.0.4 - Autodesk AutoCAD 2023.1.6
-
Autodesk AutoCAD Map 3D 2024.0.1 - Autodesk AutoCAD 2024.1.6
-
Autodesk AutoCAD Map 3D 2025.0.1 - Autodesk AutoCAD 2025.0.1
-
-
TKI PostgreSQL Provider 4.2.1
-
Comsof Fiber Designer 2019.2.2 - Comsof Fiber Designer 22.2
-
Comsof Fiber 23.1 - Comsof Fiber 23.2
-
atesio STRATEGIC 2020 - 2023
-
TKI Lizenzierung 14.0
(Only required for a manual installation on the network license server)
Note Autodesk AutoCAD Map Version:The specified versions for Autodesk AutoCAD and Map 3D are the ones for which NET was developed. Generally, newer versions can also be used. However, there have been occasional updates in the past that caused crashes in NET.
Note Autodesk AutoCAD Map 3D 2025: Currently, we advise against the productive use of the 2025 version of Autodesk AutoCAD Map 3D. In our tests, this version of Map 3D has proven to be unstable. Additionally, the compatible PGP version is still under development.
Release NET 14.0.1 in Detail
NET Design
Comsof Fiber Integration
-
An error when reading the calculation results, especially the connection information, has been fixed. This error occurred when a large number of fibers are connected to a splitter and there are a large number of fiber connections in the project.
Changes to the Data Model since NET 13.0
NET Design
Base Data Model
13.1
-
Added additional target tables in
FID_FEATURE
to the tableTC_PL_ATTR_VALUE
.-
TC_PL_BOUNDARY.FID
-
TC_PL_PARCEL.FID
-
TC_PL_ROLLOUT_AREA.FID
-
TC_PL_SUBAREA.FID
-
13.2
-
No changes to the data model - Structural update only for new forms and reports
14.0
-
Changed type of field
ABBREVIATION
tovarchar2
with a length of4
. Affected tables:-
TC_PL_BUILDING
-
TC_PL_DEMAND_POINT
-
TC_PL_HOME_POINT
-
TC_PL_LAYER_POINT
-
TC_PL_POSSIBLE_TRENCH
-
TC_PL_STREET_CL
-
-
New unique index on column
NAME
in tableTC_PL_BOUNDARY_TYPE
.
GIS-Nebenbestimmungen Data Model
13.1
-
Removed "BMVI" from all captions.
-
Added new column
BMVI_IS_TECH
inTC_PL_DEMAND_POINT
with relation toTC_PL_BMVI_TECH_IS_TBD
. -
Added new column
BMVI_PLAN_AUSB
inTC_PL_DEMAND_POINT
with relation toTC_PL_BMVI_PLAN_AUSB_TBD
. -
Added new column
BMVI_TECH_1_YEAR_INT
inTC_PL_DEMAND_POINT
with relation toTC_PL_BMVI_TECH_IS_TBD
. -
Added new column
BMVI_TECH_3_YEAR_INT
inTC_PL_DEMAND_POINT
with relation toTC_PL_BMVI_TECH_IS_TBD
. -
Added new domain table
TC_PL_BMVI_PLAN_AUSB_TBD
.-
3 - Pre-marketing is carried out
-
-
Added new domain table
TC_PL_BMVI_TECH_IS_TBD
.-
1 - FTTB/H
-
2 - HFC
-
8 - Other Technology
-
13.2
-
The captions of a few remaining identifiers have been changed from “BMVI” to “GIS-NB”. There are not structural changes.
NET Engineering
Base Data Model
13.1
-
No changes to the data model - Structural update only for new forms and reports
13.2
-
The size of the column
INFO
in the Action area (TC_ACTION_AREA
) feature class has been increased to 255 characters. -
The columns
DATE_CREATED
,DATE_MODIFIED
,USER_CREATED
andUSER_MODIFIED
were added to the following views:-
TC_M_BUILDING
-
TC_M_CLUSTER_STATISTIC
-
TC_M_SP_CABINET
-
TC_M_SP_MANHOLE
-
TC_M_SP_MARKER
-
TC_M_SP_POLE
-
TC_M_SP_SEGMENT
-
TC_M_SWITCHING_POINT
-
-
The backing table for the color table (
TC_COLOR
) was updated.-
The column AutoCAD index (
ACAD_INDEX
) is not optional anymore and got the default value 0 -
The column blue value (
B_VALUE
) is not optional anymore and got the default value 0 -
The column dashed (
DASHED
) is not optional anymore and got the default value 0 -
The column green value (
G_VALUE
) is not optional anymore and got the default value 0 -
The column position(
ORDER_ID
) is not optional anymore and got the default value 0 -
The column red value (
R_VALUE
) is not optional anymore and got the default value 0
-
13.3
-
Changed view
TC_REP_LINE_FROM_TO
.
This is an internal changed. Interface and output of the view are unchanged. -
Changed database function
TC_F_CONN_WALKER
.
Interface and result of the function remain the same. Only the processing performance got improved.
14.0
-
Update view
TC_V_COLOR
Added the columnACAD_INDEX
fromTC_COLOR
Duct Data Model
13.1
-
No changes to the data model - Structural update only for new forms and reports
13.2
-
The columns
DATE_CREATED
,DATE_MODIFIED
,USER_CREATED
andUSER_MODIFIED
were added to the following views:-
TC_M_CS_CABLE
-
TC_M_CS_DUCT
-
TC_M_SP_DUCT
-
TC_M_SP_DUCT_INSERTION
-
TC_M_SP_DUCT_TAP
-
TC_M_SP_FITTING
-
-
The field
LENGTH
got added to the viewTC_REP_SEGMENTCOSTS
, in case it was not present already.
13.3
-
No changes to the data model - Structural update only for new forms and reports
14.0
-
Altered table
TC_SP_DUCT_TYPE
-
Added column
FID_INNER_DUCT_COLOR_SCHEME
with relation toTC_NR_SCHEME.FID
-
Removed column
INNER_DUCT_COLOR_SCHEME
-
Fiber Optic Data Model
13.1
-
No changes to the data model - Structural update only for new forms and reports
-
The columns
DATE_CREATED
,DATE_MODIFIED
,USER_CREATED
andUSER_MODIFIED
were added to the following views:-
TC_M_FO_CABLE
-
TC_M_FO_CLOSURE
-
TC_M_FO_TERMINATOR
-
TC_M_FO_SP_ASSIGNMENTS
-
-
The text format of the output of the following views as fixed. There are no structure changes.
-
TC_REP_WO_FO_PATCH
-
TC_REP_WO_FO_SPLICE
-
-
The size of the column
INFO
in cable loop (TC_FO_CABLE_LOOP
) feature classes got increased to 255 characters
13.2
-
The columns
DATE_CREATED
,DATE_MODIFIED
,USER_CREATED
andUSER_MODIFIED
were added to the following views:-
TC_M_FO_CABLE
-
TC_M_FO_CLOSURE
-
TC_M_FO_TERMINATOR
-
TC_M_FO_SP_ASSIGNMENTS
-
-
The text format of the output of the following views as fixed. There are no structure changes.
-
TC_REP_WO_FO_PATCH
-
TC_REP_WO_FO_SPLICE
-
-
The size of the column
INFO
in the cable loop (TC_FO_CABLE_LOOP
) got increased to 255 characters.
13.3
-
Altered view
TC_M_FO_CLOSURE
: The columnsFID_BUILDING
andFID_STRUCTURE_POINT
were added. -
Altered view
TC_M_FO_SP_ASSIGNMENTS
.-
FID
column does not reference theTC_POINT
of the closure or the terminator, but theTC_FO_CONNECTION_LINE
-
DEV_FID
references theTC_POINT
of the closure or the terminator. -
GEOM
is not generated dynamically anymore, but fetched fromTC_FO_CONNECTION_LINE
.
-
-
Altered view
TC_M_FO_TERMINATOR
: The columnsFID_BUILDING
andFID_STRUCTURE_POINT
were added.
14.0
-
Altered table
TC_FO_CABLE_MODEL
-
Added column
FID_FIBER_COLOR_SCHEME
with relation toTC_NR_SCHEME.FID
-
Added column
FID_FIBER_NAME_SCHEME
with relation toTC_NR_SCHEME.FID
-
Removed column
FIBER_COLOR_SCHEME
-
Removed column
FIBER_NAME_SCHEME
-
Telephony Data Model
13.1
-
No changes to the data model - Structural update only for new forms and reports
13.2
-
The columns
DATE_CREATED
,DATE_MODIFIED
,USER_CREATED
andUSER_MODIFIED
were added to the following views:-
TC_M_TP_CABLE
-
TC_M_TP_CLOSURE
-
TC_M_TP_TERMINATOR
-
TC_M_TP_SP_ASSIGNMENTS
-
-
The text format of the output of the following views as fixed. There are no structure changes.
-
TC_REP_WO_TP_PATCH
-
TC_REP_WO_TP_SPLICE
-
13.3
-
Altered view
TC_M_TP_CLOSURE
: The columnsFID_BUILDING
andFID_STRUCTURE_POINT
were added. -
Altered view
TC_M_TP_SP_ASSIGNMENTS
.-
FID
column does not reference theTC_POINT
of the closure or the terminator, but theTC_TP_CONNECTION_LINE
-
DEV_FID
references theTC_POINT
of the closure or the terminator. -
GEOM
is not generated dynamically anymore, but fetched fromTC_TP_CONNECTION_LINE
.
-
-
Altered view
TC_M_TP_TERMINATOR
: The columnsFID_BUILDING
andFID_STRUCTURE_POINT
were added.
14.0
-
Altered table
TC_TP_CABLE_MODEL
-
Added column
FID_WIRE_COLOR_SCHEME
with relation toTC_NR_SCHEME.FID
-
Added column
FID_WIRE_NAME_SCHEME
with relation toTC_NR_SCHEME.FID
-
Removed column
WIRE_COLOR_SCHEME
-
Removed column
WIRE_NAME_SCHEME
-
GIS-Nebenbestimmungen Data Model
13.1
-
Added new column
BMVI_IS_TECH
inTC_TG_BUILDING
with relation toTC_BMVI_TECH_IS_TBD.ID
. -
Added new column
BMVI_PLAN_AUSB
inTC_TG_BUILDING
with relation toTC_BMVI_PLAN_AUSB_TBD.ID
. -
Added new column
BMVI_TECH_1_YEAR_INT
inTC_TG_BUILDING
with relation toTC_BMVI_TECH_IS_TBD.ID
. -
Added new column
BMVI_TECH_3_YEAR_INT
inTC_TG_BUILDING
with relation toTC_BMVI_TECH_IS_TBD.ID
. -
Added new domain table
TC_BMVI_PLAN_AUSB_TBD
.-
3 - Pre-marketing is carried out
-
-
Added new domain table
TC_BMVI_TECH_IS_TBD
.-
1 - FTTB/H
-
2 - HFC
-
8 - Other Technology
-
13.2
-
The captions of a few remaining identifiers have been changed from “BMVI” to “GIS-NB”. There are not structural changes.
13.3
-
No changes to the data model - Structural update only for new forms and reports
14.0
-
Added column
BMVI_IS_COLLOCATION
to tableTC_FO_CLOSURE
Redlining Data Model
13.1
-
Added new column
FID_STRUCTURE
inTC_RL_CLOSURE
with relation toTC_RL_STRUCTURE.FID
. -
Additional target table for the relation from
TC_RL_MEASUREMENT_POINT.FID_FEATURE
toTC_TG_BUILDING.FID
. -
Added new object class
TC_RL_MEASUREMENT_L_MODEL
. -
Added new column
FID_MODEL
inTC_RL_MEASUREMENT_LINE
with relation toTC_RL_MEASUREMENT_L_MODEL.FID
. -
Removed column
ID_TYPE
fromTC_RL_MEASUREMENT_LINE
. -
Adjusted the view
TC_M_RL_MEASUREMENT_LINE
to useFID_MODEL
instead ofID_TYPE
. -
Removed domain table
TC_RL_MEASUREMENT_L_TYPE_TBD
. -
Added new object class
TC_RL_MEASUREMENT_P_MODEL
. -
Added new column
FID_MODEL
inTC_RL_MEASUREMENT_POINT
with relation toTC_RL_MEASUREMENT_P_MODEL.FID
. -
Removed column
ID_TYPE
fromTC_RL_MEASUREMENT_POINT
. -
Adjusted the view
TC_M_RL_MEASUREMENT_POINT
to useFID_MODEL
instead ofID_TYPE
. -
Removed domain table
TC_RL_MEASUREMENT_P_TYPE_TBD
.
13.2
-
The column
FID_PARENT
was removed from the Redlining Fitting (TC_RL_FITTING
) -
The German caption of the column
CONSTRUCTION_TYPE
in Redlining Trasse (TC_RL_SEGMENT
) got changed.
13.3
-
New columns
DATE_CREATED
,DATE_MODIFIED
,USER_CREATED
andUSER_MODIFIED
got added to the following tables:-
TC_RL_SERVICE_ITEM
-
TC_RL_ATTRIBUTE
-
TC_RL_CABLE
-
TC_RL_CLOSURE
-
TC_RL_CONNECTION
-
TC_RL_DUCT
-
TC_RL_FITTING
-
TC_RL_MEASUREMENT
-
TC_RL_MEASUREMENT_LINE
-
TC_RL_MEASUREMENT_POINT
-
TC_RL_SEGMENT
-
TC_RL_STRUCTURE
-
TC_RL_TERMINATOR
-
-
New columns
DATE_CREATED
,DATE_MODIFIED
,USER_CREATED
andUSER_MODIFIED
got added to the following views:-
TC_M_RL_MEASUREMENT_LINE
-
TC_M_RL_MEASUREMENT_POINT
-
TC_M_RL_SEGMENT
-
TC_M_RL_STRUCTURE
-
TC_M_RL_TERMINATOR
-
-
New column
NAME
got added toTC_PL_SEGMENT
. -
New feature class
TC_RL_SCAN
was created. -
Reference column
FID_SCAN
with a reference toTC_RL_SCAN
was added to the following columns:-
TC_RL_CABLE
-
TC_RL_CLOSURE
-
TC_RL_DUCT
-
TC_RL_FITTING
-
TC_RL_MEASUREMENT_LINE
-
TC_RL_MEASUREMENT_POINT
-
TC_RL_SEGMENT
-
TC_RL_STRUCTURE
-
TC_RL_TERMINATOR
-
-
New column
DATE_SYNC
got added toTC_RL_MEASUREMENT
. -
Reference column
ID_TYPE_SURVEY
with a reference toTC_SP_LINE_TYPE_TBD
got added toTC_RL_MEASUREMENT_LINE
. -
Reference column
ID_TYPE_SURVEY
with a reference toTC_SP_POINT_TYPE_TBD
got added toTC_RL_MEASUREMENT_POINT
.
-
Added column
SOURCE_OBJECT
to the following tables-
TC_RL_CABLE
-
TC_RL_CLOSURE
-
TC_RL_CONNECTION
-
TC_RL_DUCT
-
TC_RL_FITTING
-
TC_RL_MEASUREMENT_LINE
-
TC_RL_MEASUREMENT_POINT
-
TC_RL_SEGMENT
-
TC_RL_STRUCTURE
-
TC_RL_TERMINATOR
-
-
Added new value to the domain table
TC_RL_CHECKED_STATE_TBD
-
3 -
BLOCKED
- Blocked
-
NET Field Survey
Base Data Model
13.3
-
No changes to the data model - Structural update only for new forms and reports
14.0
-
No changes to the data model - Structural update only for new forms and reports
GIS-Nebenbestimmungen Data Model
13.2
-
The captions of a few remaining identifiers have been changed from “BMVI” to “GIS-NB”. There are not structural changes.
DocPack
13.2
-
A new view for the plot sequences has been added (
TC_V_PLOT_SEQUENCE
)
Changes to the dialogs since NET 13.0
NET Design
Base Data Model
13.1
-
New dialog for Boundary (
TC_PL_BOUNDARY
): Attribute Value (TC_PL_ATTR_VALUE
) -
New dialog for Parcel (
TC_PL_PARCEL
): Attribute Value (TC_PL_ATTR_VALUE
) -
New dialog for Rollout Area (
TC_PL_ROLLOUT_AREA
): Attribute Value (TC_PL_ATTR_VALUE
) -
New dialog for Subarea (
TC_PL_SUBAREA
): Attribute Value (TC_PL_ATTR_VALUE
) -
New references from Cable Type (
TC_PL_CABLE_TYPE.FID
)-
to Building (
TC_PL_BUILDING.FID_FORCED_CABLE_TYPE
) -
to Demand Point (
TC_PL_DEMAND_POINT.FID_FORCED_CABLE_TYPE
)
-
13.2
-
The number of decimal places for the display has been set to 2.
-
Boundary (
TC_PL_BOUNDARY
) - Length in m (LENGTH
) -
Boundary (
TC_PL_BOUNDARY
) - Width (WIDTH
) -
Building → Number of residents (
TC_PL_RESIDENT
) - Adoption rate (ADOPTION_RATE
) -
Building → Number of residents (
TC_PL_RESIDENT
) - Expected revenue (EXPECTED_REVENUE
) -
Demand Point → Number of residents (
TC_PL_RESIDENT
) - Adoption rate (ADOPTION_RATE
) -
Demand Point → Number of residents (
TC_PL_RESIDENT
) - Expected revenue (EXPECTED_REVENUE
) -
Number of residents (
TC_PL_RESIDENT
) - Adoption rate (ADOPTION_RATE
) -
Number of residents (
TC_PL_RESIDENT
) - Expected revenue (EXPECTED_REVENUE
) -
Result Kabelloop (
TC_PL_OUT_CABLE_LOOP
) - Length (LENGTH
)
-
14.0
-
Updated mandatory flags and enabled the client side unique check for all dialog controls according to the database definition.
This update affects every dialog and updates the flags according to the definition in the database.
GIS-Nebenbestimmung Data Model
13.1
-
Dialog for Demand Point (
TC_PL_DEMAND_POINT
):-
Changed control for "Technology within one year" from text field to dropdown. Database field changed from
BMVI_TECH_1_YEAR
toBMVI_TECH_1_YEAR_INT
. -
Changed control for "Technology within three years" from text field to dropdown. Database field changed from
BMVI_TECH_3_YEAR
toBMVI_TECH_3_YEAR_INT
. -
Changed control for "Technology Is Supply" from text field to dropdown. Database field changed from
BMVI_TECH_IS
toBMVI_IS_TECH
. -
Added new dropdown "Expansion Plan" (
BMVI_PLAN_AUSB
)
-
13.2
-
The caption “BMVI” has been replaced by “GIS-NB” in the following dialogs:
-
Cable (
TC_PL_CABLE
) -
Duct (
TC_PL_DUCT
) -
Expansion area (
TC_PL_EXPANSION_AREA
) -
Layer Point (
TC_PL_LAYER_POINT
) -
Market survey (
TC_PL_MARKET_SURVEY
) -
Possible trench (
TC_PL_POSSIBLE_TRENCH
) -
Structure (
TC_PL_STRUCTURE
)
-
-
Controls related to GIS-NB have been moved to the GIS-NB tab.
-
Expansion area (
TC_PL_EXPANSION_AREA
) -
Foreign area (
TC_PL_FOREIGN_AREA
) -
Political area (
TC_PL_POLITICAL_AREA
) -
White spot (
TC_PL_WHITE_SPOT
)
-
-
The number of decimal places for the display has been set to 2.
-
Expansion area (
TC_PL_EXPANSION_AREA
) - Area (AREA
) -
Foreign area (
TC_PL_FOREIGN_AREA
) - Area (AREA
) -
Market survey (
TC_PL_MARKET_SURVEY
) - Area (AREA
) -
Political area (
TC_PL_POLITICAL_AREA
) - Area (AREA
) -
White spot (
TC_PL_WHITE_SPOT
) - Area (AREA
)
-
NET Engineering
Base Data Model
13.2
-
The number of decimal places for the display has been set to 2.
-
Action Area (
TC_ACTION_AREA
) - Area (AREA
) -
Action Area Label (
TC_ACTION_AREA_TBL
) - Orientation (ORIENTATION
) -
Cluster Grid (
TC_CLUSTER_GRID
) - Area (AREA
) -
Cabinet Label (
TC_SP_CABINET_TBL
) - Orientation (ORIENTATION
) -
Manhole Label (
TC_SP_MANHOLE_TBL
) - Orientation (ORIENTATION
) -
Survey Plan Point (
TC_SP_POINT
) - Orientation (ORIENTATION
) -
Pole Label (
TC_SP_POLE_TBL
) - Orientation (ORIENTATION
) -
Segment Label (
TC_SP_SEGMENT_TBL
) - Orientation (ORIENTATION
) -
Switching Point Label (
TC_SP_SWITCHING_POINT_TBL
) - Orientation (ORIENTATION
) -
Building Label (
TC_TG_BUILDING_TBL
) - Orientation (ORIENTATION
) -
Topography point (
TC_TG_POINT
) - Orientation (ORIENTATION
) -
Topography cluster (
TC_TG_POLYGON
) - Area (AREA
) -
Street Label (
TC_TG_STREET_TBL
) - Orientation (ORIENTATION
)
-
-
All Info fields (
INFO
) have been set to have the height of 51, to support multiple lines and automatically apply line breaks. Changes were done in the following dialogs:-
Action area (
TC_ACTION_AREA
) -
Element library (
TC_ELEMENT_LIBRARY
) -
Line (
TC_LINE
) -
Point (
TC_POINT
) -
Drilling rig (
TC_SP_DRILLING_RIG
) -
Marker (
TC_SP_MARKER
) -
Marker model (
TC_SP_MARKER_MODEL
) -
Patch panel (
TC_SP_PATCH_PANEL
) -
Patch panel model (
TC_SP_PATCH_PANEL_MODEL
) -
Rack panel (
TC_SP_RACK_PANEL
) -
Rack panel model (
TC_SP_RACK_PANEL_MODEL
) -
Status (
TC_STATUS
) -
Switching point model (
TC_SWITCHING_POINT_MODEL
) -
Topography point (
TC_TG_POINT
) -
Topography cluster (
TC_TG_POLYGON
)
-
13.3
-
Dialog definitions for the following views got removed and replaced with a redirect to the base table.
-
TC_V_COLOR
-
TC_V_CONN
-
TC_V_CONN_DETAILS
-
TC_V_CONN_DETAILS_PERF
-
TC_CONN_DETAILS_TO
-
14.0
-
Fixed the multi reference control on the Line (
TC_LINE
) dialog. References to the connection lines are now properly resolved. -
Updated the dialog for cabinets (
TC_SP_CABINET
), manholes (TC_SP_MANHOLE
) and poles (TC_SP_POLE)
-
Added a reference to the connected ducts
-
Fixed the positioning of the controls
-
-
Updated mandatory flags and enabled the client side unique check for all dialog controls according to the database definition.
This update affects every dialog and updates the flags according to the definition in the database.
Duct Data Model
13.2
-
The number of decimal places for the display has been set to 2.
-
Duct insertion label (
TC_SP_DUCT_INSERTION_TBL
) - Orientation (ORIENTATION
) -
Duct tap line (
TC_SP_DUCT_TAP_LINE
) - Length (LENGTH
) -
Duct tap line label (
TC_SP_DUCT_TAP_LINE_TBL
) - Orientation (ORIENTATION
) -
Duct tap label (
TC_SP_DUCT_TAP_TBL
) - Orientation (ORIENTATION
) -
Duct label (
TC_SP_DUCT_TBL
) - Orientation (ORIENTATION
) -
Duct (
TC_SP_FITTING_TBL
) - Orientation (ORIENTATION
)
-
-
All Info fields (
INFO
) have been set to have the height of 51, to support multiple lines and automatically apply line breaks. Changes were done in the following dialogs:-
Duct tap model (
TC_SP_DUCT_TAP_MODEL
)
-
13.3
-
New projection added to
TC_TG_BUILDING
pointing the the duct terminators inside the building. -
Dialog definitions for the following views got removed and replaced with a redirect to the base table.
-
TC_V_BREAKDOWN_LINES
-
14.0
-
Dialog Duct type (
TC_SP_DUCT_TYPE
)-
Selection for color scheme: Changed referenced database field from
INNER_DUCT_COLOR_SCHEME
toFID_INNER_DUCT_COLOR_SCHEME
-
-
Updated mandatory flags and enabled the client side unique check for all dialog controls according to the database definition.
This update affects every dialog and updates the flags according to the definition in the database.
Fiber Optic Data Model
13.1
-
Dialog for Fiber Optic Splice (
TC_FO_SPLICE
):-
New named filters:
-
Show splices
-
Show stored fibers
-
Show uncut fibers in BA
-
Show uncut fibers
-
-
New SQL Label "Splice Type" (
$SQLLABELSPLICETYPE
) -
Corrected positioning of Document Management (
$DOCUMENTMANAGER
)
-
13.2
-
The number of decimal places for the display has been set to 2.
-
FO cable loop label (
TC_FO_CABLE_LOOP_TBL
) - Orientation (ORIENTATION
) -
FO cable model (
TC_FO_CABLE_MODEL
) - Diameter (DIAMETER
) -
FO connector label (
TC_FO_CONNECTOR_TBL
) - Orientation (ORIENTATION
) -
FO fiber label (
TC_FO_FIBER_TBL
) - Orientation (ORIENTATION
) -
FO patch data (
TC_FO_PATCH_DATA
) - Attenuation (ATTENUATION
) -
FO patch fiber label (
TC_FO_PATCH_FIBER_TBL
) - Orientation (ORIENTATION
) -
FO patch label (
TC_FO_PATCH_TBL
) - Orientation (ORIENTATION
) -
FO splice graphics label (
TC_FO_SPLICE_GRAPHICS_TBL
) - Orientation (ORIENTATION
) -
FO splice label (
TC_FO_SPLICE_TBL
) - Orientation (ORIENTATION
) -
FO splitter path label (
TC_FO_SPLITTER_PATH_TBL
) - Orientation (ORIENTATION
) -
FO splitter label (
TC_FO_SPLITTER_TBL
) - Orientation (ORIENTATION
) -
FO terminator label (
TC_FO_TERMINATOR_TBL
) - Orientation (ORIENTATION
)
-
-
All Info fields (
INFO
) have been set to have the height of 51, to support multiple lines and automatically apply line breaks. Changes were done in the following dialogs:-
FO cable loop (
TC_FO_CABLE_LOOP
) -
FO closure model (
TC_FO_CLOSURE_MODEL
)
-
-
New API controls have been added to the FO closure (
TC_FO_CLOSURE
) and the FO terminator (TC_FO_TERMINATOR
)-
$ENDINGLINECOMPLEX
-
$STARTINGLINECOMPLEX
-
-
Dialog FO splice (
TC_FO_SPLICE
) - The display for the connected splitters got corrected. The queries of the controls$SQLLABELSPLITTER1
and$SQLLABELSPLITTER2
got fixed.
13.3
-
New projection added to
TC_TG_BUILDING
pointing the the fiber optic terminators inside the building. -
Dialog definitions for the following views got removed and replaced with a redirect to the base table.
-
TC_V_FO_CONN_FIBERTOTRAY
-
TC_V_FO_CONN_FIBER_CONN
-
TC_V_FO_CONN_PATCHFIBER
-
TC_V_FO_CONN_SPLICE
-
TC_V_FO_CONN_SPLITTER
-
TC_V_FO_TRAY
-
TC_V_FO_UNCUT_FIBERS
-
TC_V_FO_WIRING
-
TC_V_SPLICE_OVERVIEW
-
14.0
-
Dialog fiber optic cable type (
TC_FO_CABLE_MODEL
)-
Selection for color scheme: Changed referenced database field from
FIBER_COLOR_SCHEME
toFID_FIBER_COLOR_SCHEME
-
Selection for naming scheme: Changed referenced database field from
FIBER_NAME_SCHEME
toFID_FIBER_NAME_SCHEME
-
-
Updated mandatory flags and enabled the client side unique check for all dialog controls according to the database definition.
This update affects every dialog and updates the flags according to the definition in the database.
Telephony Data Model
13.2
-
The number of decimal places for the display has been set to 2.
-
Telephony cable loop (
TC_TP_CABLE_LOOP
) - Orientation (ORIENTATION
) -
Telephony cable model (
TC_TP_CABLE_MODEL
) - Diameter (DIAMETER
) -
Telephony cable label (
TC_TP_CABLE_TBL
) - Orientation (ORIENTATION
) -
Telephony closure label (
TC_TP_CLOSURE_TBL
) - Orientation (ORIENTATION
) -
Telephony patch data (
TC_TP_PATCH_DATA
) - Attenuation (ATTENUATION
) -
Telephony patch label (
TC_TP_PATCH_TBL
) - Orientation (ORIENTATION
) -
Telephony pin data (
TC_TP_PIN_DATA
) - Attenuation (ATTENUATION
) -
Telephony splice data (
TC_TP_SPLICE_DATA
) - Attenuation (ATTENUATION
) -
Telephony splice graphics label (
TC_TP_SPLICE_GRAPHICS_TBL
) - Orientation (ORIENTATION
) -
Telephony terminator label (
TC_TP_TERMINATOR_TBL
) - Orientation (ORIENTATION
) -
Telephony wire data (
TC_TP_WIRE_DATA
) - Attenuation (ATTENUATION
)
-
-
New API controls have been added to the Telephony closure (
TC_TP_CLOSURE
) and the Telephony terminator (TC_TP_TERMINATOR
)-
$ENDINGLINECOMPLEX
-
$STARTINGLINECOMPLEX
-
13.3
-
New projection added to
TC_TG_BUILDING
pointing the the telephony terminators inside the building. -
Dialog definitions for the following views got removed and replaced with a redirect to the base table.
-
TC_V_TP_CONN_DETAILS
-
TC_V_TP_CONN_SPLICE
-
TC_V_TP_CONN_WIRE_PIN
-
TC_V_TP_PINS
-
TC_V_TP_WIRING
-
14.0
-
Dialog telephony cable type (
TC_TP_CABLE_MODEL
)-
Selection for color scheme: Changed referenced database field from
WIRE_COLOR_SCHEME
toFID_WIRE_COLOR_SCHEME
-
Selection for naming scheme: Changed referenced database field from
WIRE_NAME_SCHEME
toFID_WIRE_NAME_SCHEME
-
-
Updated mandatory flags and enabled the client side unique check for all dialog controls according to the database definition.
This update affects every dialog and updates the flags according to the definition in the database.
Redlining Data Model
13.1
-
Dialog for Redlining Closure (
TC_PL_CLOSURE
):-
New reference field for Redlining Structure (
FID_STRUCTURE
) -
Corrected positioning of Redlining Source Object (
SOURCE_OBJECT
)
-
-
Dialog for Measurement Line (
TC_RL_MEASUREMENT_LINE
):-
Replaced reference to type
ID_TYPE
withFID_MODEL
-
Corrected positioning of all controls
-
-
New dialog for Measurement Line Model (
TC_RL_MEASUREMENT_L_MODEL
) -
Dialog for Measurement Point (
TC_RL_MEASUREMENT_POINT
):-
Extended target tables for parent object (
FID_PARENT
) to include Building (TC_TG_BUILDING
) -
Replaced reference to type
ID_TYPE
withFID_MODEL
-
Corrected positioning of all controls
-
-
New dialog for Measurement Point Model (
TC_RL_MEASUREMENT_P_MODEL
) -
Corrected positioning of Source Object (
SOURCE_OBJECT
) in Redlining Segment (TC_RL_SEGMENT
) -
Corrected positioning of Source Object (
SOURCE_OBJECT
) in Redlining Structure (TC_RL_STRUCTURE
) -
Corrected positioning of Source Object (
SOURCE_OBJECT
) in Redlining Terminator (TC_RL_TERMINATOR
)
13.2
-
The links to the online help got updated in the following dialogs
-
Redlining attribute (
TC_RL_ATTRIBUTE
) -
Redlining cable (
TC_RL_CABLE
) -
Redlining closure (
TC_RL_CLOSURE
) -
Redlining connection (
TC_RL_CONNECTION
) -
Redlining duct (
TC_RL_DUCT
) -
Redlining fitting (
TC_RL_FITTING
) -
Redlining measurement (
TC_RL_MEASUREMENT
) -
Redlining measurement line (
TC_RL_MEASUREMENT_LINE
) -
Redlining measurement point (
TC_RL_MEASUREMENT_POINT
) -
Redlining segment (
TC_RL_SEGMENT
) -
Redlining service item (
TC_RL_SERVICE_ITEM
) -
Redlining structure (
TC_RL_STRUCTURE
) -
Redlining terminator (
TC_RL_TERMINATOR
)
-
-
A new reference to the Redlining service item (
$REF_TC_RL_SERVICE_ITEM
) has been added to the following dialogs:-
Redlining closure (
TC_RL_CLOSURE
) -
Redlining fitting (
TC_RL_FITTING
) -
Redlining segment (
TC_RL_SEGMENT
) -
Redlining structure (
TC_RL_STRUCTURE
) -
Redlining terminator (
TC_RL_TERMINATOR
)
-
-
The reference to the Redlining fitting (
$REF_TC_RL_FITTING
) has been removed from the dialog Redlining duct (TC_RL_DUCT
) -
The reference to the Redlining fitting (
$REF_TC_RL_FITTING
) has been removed from the dialog Redlining segment (TC_RL_SEGMENT
) -
The reference to the parent object (
FID_PARENT
) has been removed from the dialog for the Redlining fitting (TC_RL_FITTING
)
13.3
-
A new control (
FID_SCAN
) with a reference to the Redlining Scan table got added to the following dialogs:-
TC_RL_CABLE
-
TC_RL_CLOSURE
-
TC_RL_DUCT
-
TC_RL_FITTING
-
TC_RL_MEASUREMENT_LINE
-
TC_RL_MEASUREMENT_POINT
-
TC_RL_SEGMENT
-
TC_RL_STRUCTURE
-
TC_RL_TERMINATOR
-
-
A set of new controls got added to the Redlining Measurement (
TC_RL_MEASUREMENT
) containing the number of individual features that got added during the last pull from NET Build. -
New selection for the survey plan type stored in
TC_RL_MEASUREMENT_L_MODEL
-
New selection for the survey plan type stored in
TC_RL_MEASUREMENT_P_MODEL
-
New text box for the
NAME
added toTC_RL_SEGMENT
-
Completely new dialog for
TC_RL_SCAN
14.0
-
Redlining cable (
TC_RL_CABLE
)-
Fixed tab-key sequence in the dialog
-
New text input control for column
SOURCE_OBJECT
-
-
Redlining closure (
TC_RL_CLOSURE
) - New text input control for columnSOURCE_OBJECT
-
Redlining connection (
TC_RL_CONNECTION
)-
Positionierung der Steuerelemente im Formular korrigiert
-
New text input control for column
SOURCE_OBJECT
-
-
Redlining duct(
TC_RL_DUCT
)-
Positionierung der Steuerelemente im Formular korrigiert
-
New text input control for column
SOURCE_OBJECT
-
-
Redlining fitting(
TC_RL_FITTING
)-
Fixed tab-key sequence in the dialog
-
New text input control for column
SOURCE_OBJECT
-
-
Redlining measurement line (
TC_RL_MEASUREMENT_LINE
) - New text input control for columnSOURCE_OBJECT
-
Redlining measurement point (
TC_RL_MEASUREMENT_POINT
) - New text input control for columnSOURCE_OBJECT
-
Redlining segment (
TC_RL_SEGMENT
) - New text input control for columnSOURCE_OBJECT
-
Redlining structure (
TC_RL_STRUCTURE
) - New text input control for columnSOURCE_OBJECT
-
Redlining terminator (
TC_RL_TERMINATOR
) - New text input control for columnSOURCE_OBJECT
-
Updated mandatory flags and enabled the client side unique check for all dialog controls according to the database definition.
This update affects every dialog and updates the flags according to the definition in the database.
GIS-Nebenbestimmungen Data Model
13.1
-
Dialog for Building (
TC_TG_BUILDING
):-
Changed control for "Technology within one year" from text field to dropdown. Database field changed from
BMVI_TECH_1_YEAR
toBMVI_TECH_1_YEAR_INT
. -
Changed control for "Technology within three years" from text field to dropdown. Database field changed from
BMVI_TECH_3_YEAR
toBMVI_TECH_3_YEAR_INT
. -
Changed control for "Technology Is Supply" from text field to dropdown. Database field changed from
BMVI_TECH_IS
toBMVI_IS_TECH
. -
Added new dropdown "Expansion Plan" (
BMVI_PLAN_AUSB
)
-
13.2
-
The number of decimal places for the display has been set to 2.
-
Expansion area (
TC_BMVI_EXPANSION_AREA
) - Area (AREA
) -
Foreign area (
TC_BMVI_FOREIGN_AREA
) - Area (AREA
) -
Market survey (
TC_BMVI_MARKET_SURVEY
) - Area (AREA
) -
Political area (
TC_BMVI_POLITICAL_AREA
) - Area (AREA
) -
Supply area (
TC_BMVI_SUPPLY_AREA
) - Area (AREA
) -
White spot (
TC_BMVI_WHITE_SPOT
) - Area (AREA
) -
Building (
TC_TG_BUILDING
) - Loss (BMVI_LOSS
)
-
13.3
-
Update of the spatial queries for the living and business units, as well as schools, public institutions and hospitals in
TC_BMVI_WHITE_SPOTS
andTC_BMVI_EXPANSION_AREA
. Building that are only partially inside of the cluster, will now be counted as well.
14.0
-
Added new checkbox for the column
BMVI_IS_COLLOCATION
in dialog for the fiber optic closure (TC_FO_CLOSURE
) -
Updated mandatory flags and enabled the client side unique check for all dialog controls according to the database definition.
This update affects every dialog and updates the flags according to the definition in the database.
Changes of the reports since NET 13.0
NET Engineering
Base Data Model
13.1
-
Support function to identify the location of images was updated in all reports.
13.2
-
The base filter of the reports were changed, to prevent an error showing up in case there are no rows selected in the corresponding dialog.
-
NET network overview service (
NET Network Overview Service
) -
NET network overview service (just points) (
NET Network Overview of Service(just Points)
) -
NET point table (
NET Point Table
) -
NET reports (
NET Reports
) -
NET segment cost (
NET Segment Cost
) -
NET work order (
NET Work Order
)
-
-
Replaced automatic line break with with manual line break in the report NET work order (
NET Work Order
).
13.3
-
The base filter for the reports got changed for Oracle databases, to allow the reports being created once again without an error. The following reports got changed.
-
NET network overview service (
NET Network Overview Service
) -
NET network overview service (just points) (
NET Network Overview of Service(just Points)
) -
NET point table (
NET Point Table
) -
NET reports (
NET Reports
) -
NET segment cost (
NET Segment Cost
) -
NET work order (
NET Work Order
)
-
Duct Data Model
13.1
-
The vertical text alignment has been fixed in the columns for the start and end node in the “duct tap connections” report.
-
Support function to identify the location of images was updated in all reports.
13.2
-
The base filter of the reports were changed, to prevent an error showing up in case there are no rows selected in the corresponding dialog.
-
NET duct end overview (
Duct End Overview
)
-
-
NET duct tap label (
NET Duct Tap Label
) - color 2 of the duct on the right side fixed
13.3
-
The base filter for the reports got changed for Oracle databases, to allow the reports being created once again without an error. The following reports got changed.
-
NET duct end overview (
Duct End Overview
)
-
Fiber Optic Data Model
13.1
-
Support function to identify the location of images was updated in all reports.
13.2
-
The base filter of the reports were changed, to prevent an error showing up in case there are no rows selected in the corresponding dialog.
-
NET cable cost (
NET Cable Cost)
-
NET FO cable section brief overview (
NET FO Cable Section Brief Overview
) -
NET FO cable section service customer (
NET FO Cable Section Service Customer)
-
NET FO cable section without trunk (
NET FO Cable Section Without Trunk)
-
NET FO cable section (
NET FO Cable Section)
-
NET FO cable trunk duct route (
NET FO Cable Trunk Duct Route)
-
NET FO closure trays (
NET FO Closure Trays)
-
NET FO connector used at switching point (
NET FO Connector Used at Switching Point)
-
NET FO connector used at terminator (
NET FO Connector Used at Terminator)
-
NET FO connector used with service at switching point (
NET FO Connector Used with Service at Switching Point
) -
NET FO connector used with service at terminator (
NET FO Connector Used with Service at Terminator
) -
NET FO connector at switching point (
NET FO Connector at Switching Point
) -
NET FO connector at terminator (
NET FO Connector at Terminator
) -
NET FO patch overview from connectors (
NET FO Patch Overview from Connectors
) -
NET FO patches in switching point (
NET FO Patches in Switching Point
) -
NET FO patches in terminator (
NET FO Patches in Terminator
) -
NET FO terminator overview (
NET FO Terminator Overview
)
-
13.3
-
The base filter for the reports got changed for Oracle databases, to allow the reports being created once again without an error. The following reports got changed.
-
NET cable cost (
NET Cable Cost)
-
NET FO cable section brief overview (
NET FO Cable Section Brief Overview
) -
NET FO cable section service customer (
NET FO Cable Section Service Customer)
-
NET FO cable section without trunk (
NET FO Cable Section Without Trunk)
-
NET FO cable section (
NET FO Cable Section)
-
NET FO cable trunk duct route (
NET FO Cable Trunk Duct Route)
-
NET FO closure trays (
NET FO Closure Trays)
-
NET FO connector used at switching point (
NET FO Connector Used at Switching Point)
-
NET FO connector used at terminator (
NET FO Connector Used at Terminator)
-
NET FO connector used with service at switching point (
NET FO Connector Used with Service at Switching Point
) -
NET FO connector used with service at terminator (
NET FO Connector Used with Service at Terminator
) -
NET FO connector at switching point (
NET FO Connector at Switching Point
) -
NET FO connector at terminator (
NET FO Connector at Terminator
) -
NET FO patch overview from connectors (
NET FO Patch Overview from Connectors
) -
NET FO patches in switching point (
NET FO Patches in Switching Point
) -
NET FO patches in terminator (
NET FO Patches in Terminator
) -
NET FO terminator overview (
NET FO Terminator Overview
)
-
Telephony Data Model
13.1
-
Support function to identify the location of images was updated in all reports.
13.2
-
The base filter of the reports were changed, to prevent an error showing up in case there are no rows selected in the corresponding dialog.
-
NET Telephony cable section brief overview (
NET TP Cable Section Brief Overview
) -
NET Telephony cable section service customer (
NET TP Cable Section Service Customer
) -
NET Telephony cable section without trunk (
NET TP Cable Section without Trunk
) -
NET Telephony cable section (
NET TP Cable Section
) -
NET Telephony cable trunk duct route (
NET TP Cable Trunk Duct Route
) -
NET Telephony network overview template (
NET TP Network Overview Template
) -
NET Telephony patches in switching point (
NET TP Patches in Switching point
) -
NET Telephony patches in terminator (
NET TP Patches in Terminator
) -
NET Telephony pins in switching point (
NET TP Pins in Switching point
) -
NET Telephony pins in terminator (
NET TP Pins in Terminator
) -
NET Telephony splice overview closure (
NET TP Splice Overview Closure
) -
NET Telephony splice overview terminator (
NET TP Splice Overview Terminator
)
-
13.3
-
The base filter for the reports got changed for Oracle databases, to allow the reports being created once again without an error. The following reports got changed.
-
NET Telephony cable section brief overview (
NET TP Cable Section Brief Overview
) -
NET Telephony cable section service customer (
NET TP Cable Section Service Customer
) -
NET Telephony cable section without trunk (
NET TP Cable Section without Trunk
) -
NET Telephony cable section (
NET TP Cable Section
) -
NET Telephony cable trunk duct route (
NET TP Cable Trunk Duct Route
) -
NET Telephony network overview template (
NET TP Network Overview Template
) -
NET Telephony patches in switching point (
NET TP Patches in Switching point
) -
NET Telephony patches in terminator (
NET TP Patches in Terminator
) -
NET Telephony pins in switching point (
NET TP Pins in Switching point
) -
NET Telephony pins in terminator (
NET TP Pins in Terminator
) -
NET Telephony splice overview closure (
NET TP Splice Overview Closure
) -
NET Telephony splice overview terminator (
NET TP Splice Overview Terminator
)
-