Summary
NET 15.0.2 is a maintenance release focusing on stability and productivity in NET Design, NET Engineering, NET Operations and the NET REST Server. It fixes issues in the atesio and Comsof integrations, optimizes imports, workflows, forms and the Connection Editor, and improves TNIM import validations. In addition, the Documentation Pack has been extended with an Excel-based duct end overview, the fault workflows in NET Operations have been enhanced, and the ImBatch client of NET Enterprise now also supports ONTs.
Supported Software
- Autodesk AutoCAD Map 3D
- Autodesk AutoCAD Map 3D 2024.0.1 - Autodesk AutoCAD 2024.1.8
- Autodesk AutoCAD Map 3D 2025.0.2 - Autodesk AutoCAD 2025.1.3
- Autodesk AutoCAD Map 3D 2026.0.2 - Autodesk AutoCAD 2026.1
- TKI PostgreSQL Provider 4.2.1 and later
- Comsof Fiber Designer 2019.2.2 - Comsof Fiber Designer 22.2
- Comsof Fiber 23.1 - Comsof Fiber 25.1
- atesio STRATEGIC 2020 - 2024
- TKI Lizenzierung 14.0
(Only required for a manual installation on the network license server)
Note on the AutoCAD Map 3D versions
Autodesk has released an update that unfortunately causes compatibility issues with NET and PGP.
This affects Autodesk AutoCAD Map 3D 2024. The latest supported versions are Map 3D 2024.0.1 and AutoCAD 2024.1.8.
If the update to Map 3D 2024.0.2 is installed, neither NET nor PGP will work.
Please check your installed AutoCAD Map 3D version and pay attention to these two version details when doing so:
Release NET 15.0.1 in Detail
NET Design
atesio Integration
- Fixed a bug that caused result cables and ducts with the attribute ‘deployed’ set to ‘false’ to not be visible in the forms after an atesio calculation.
- Fixed a bug where the output cluster were not being linked to the default cluster after calculation with atesio.
Comsof Fiber Integration
- It is now possible to read in calculation results that include demand points which are connected in the distribution layer.
NET Engineering
Import
- The number format field has been removed from the CSV import.
- When importing csv, excel, and kml files, records with geometries that do not match the geometry type of target object class selected on page 1 are now logged as errors in the import protocol
- During the general import, the progress bar now displays the import progress evenly.
- The error when importing into a utility class when using a PostgreSQL database with the general import has been fixed.
- When changing the settings, the geometry columns are now automatically reset.
- A bug was fixed that prevented the data preview in the CSV import from opening when an incorrect delimiter was selected.
- The value of the Geometrie columns are converted correctly with floating numbers and Integers
Workflows
- The Breakdown analysis is now displayed correctly again even at higher scales.
Connection editor
- In the connection editor, when opening a connection action with fibers or wires for the first time, the first incoming cable is preselected on the left and the first outgoing cable on the right, according to the flow direction.
- A bug in the calculation of free splice places in the connection editor when using work orders has been fixed.
Dialogs
- In the “FO Closure”, “FO Terminator”, “TP Closure” and “TP Terminator” forms, the behavior regarding marking and right-clicking on one or more data records (opening the context menu) has been optimized for incoming and outgoing cables.
- When adding cables to a TP or FO device, an error overview is now displayed if cables cannot be connected.
- In the “FO Closure”, “FO Terminator”, “TP Closure” and “TP Terminator” forms, the error message now only appears once, as expected, when more than one device is assigned to one side of a cable section.
Reports
- A bug was fixed that caused filter options to appear twice in the new CO overview.
- Splice plan from tracing could not be generated for telephony cables. This issue has been resolved.
GIS-Nebenbestimmungen
- GIS-NB Export: In the “Leerrohre” layer, existing empty ducts are marked as “Bestand” in the LR_Sonst column for phase 2 from version 4.1 onwards, provided that the column is not used for any other purpose.
- GIS-NB: Correction in handling curves in the layer “Leerrohre”
TNIM
- The TNIN v2.1 import validations for splices, fibers, splitter paths and geometry checks have been improved.
- The matching of persons in the TNIM v2.1 import has been improved. Entries from the import file are now more reliably assigned to existing records in the database.
Documentation Pack
- The DocPack now also supports exporting the duct end overview in Excel format.
NET Operations
Workflows
- In the workflows “Create breakdown (from connector)” and “Create breakdown (from pin)”, there is now a button for marking the potential breakdown position.
- In the “Create breakdown (from connector)” and “Create breakdown (from pin)” workflows, right-clicking on a connector/pin now opens a new context menu with functions for opening the form or connection overview or for highlighting the network path.
NET REST Server
General
- ONT support has been added to the ImBatch client for NET Enterprise.
Changes to the Data Model since NET 14.0
NET Design
Base Data Model
14.1
- New feature class “Surface areas” (
TC_PL_SURFACE_AREA)
14.2
- New entry for the domain table “demand type” (
TC_PL_DEMAND_CONN_TYPE_TBD)- 15 - No private connection
14.3
- New entry for the domain table “Cluster type” (
TC_PL_CLUSTER_TYPE_TBD)- 4 - Duct cluster
15.0
- New entry for the domain table “trench class” (
TC_PL_TRENCH_CLASS_TBD)- 12 - CO transition
NET Engineering
Base Data Model
14.1
- No changes to the data model - Structural update only for new forms and reports
14.2
- New columsn for data source (
FID_TNIM_SOURCE) and source key (TNIM_SOURCE_KEY) in the following tables:TC_CLUSTERTC_PERSONTC_SWITCHING_POINTTC_SP_PATCH_PANELTC_SP_PATCH_PANEL_MODELTC_SP_RACK_PANELTC_SP_RACK_PANEL_MODELTC_SP_CABINET_MODELTC_SP_MANHOLE_MODELTC_SP_MARKERTC_SP_MARKER_MODELTC_SP_POLE_MODELTC_SP_SEGMENT_MODELTC_TG_BUILDINGTC_TG_BUILDING_UNITTC_LINETC_POINT
- New feature class “data source” (
TNIM_SOURCE)
14.3
- No changes to the data model - Structural update only for new forms and data checks
15.0
- The columns
FIELDCOLOR1andFIELDCOLOR2have been removed from the table “Number Scheme Type” (TC_NR_SCHEME_TYPE). - A new field has been added to Status (
TC_STATUS) for Status Category (ID_STATUS_CATEGORY), with a link to the Status Category table (TC_STATUS_CATEGORY_TBD). - A new column “Name” (
NAME) has been added to Building Unit (TC_TG_BUILDING_UNIT). - The column “Connector” (
FID_CONNECTOR) has been removed from Building Unit (TC_TG_BUILDING_UNIT).
It is replaced by the ONT tables that have been added to the fiber data model. - New object class “Insertion Grid” (
TC_SP_INSERTION_GRID) added. - New object class “Insertion Grid Type” (
TC_SP_INSERTION_GRID_MDL) added. - New object class “Insertion Grid Group” (
TC_SP_INSERTION_GROUP) added. - New object class “Insertion Grid Group Template” (
TC_SP_INSERTION_GROUP_TBL) added. - New domain table for Status Category (
ID_STATUS_CATEGORY) added.
The following predefined values are included in the domain:- 1 – Planning
- 2 – Existing
- 3 – Under Construction
- 4 – Built
- 5 – Reserve
- 6 – Discarded
- 7 – Blocked
- 8 – Decommissioned
- 9 – Unknown
Duct Data Model
14.1
- No changes to the data model - Structural update only for new forms and reports
14.2
- New columsn for data source (
FID_TNIM_SOURCE) and source key (TNIM_SOURCE_KEY) in the following tables:TC_SP_DUCT_TYPETC_SP_DUCT_BUNDLETC_SP_DUCT_INSERTIONTC_SP_DUCT_INSERTION_MDLTC_SP_FITTING_MODEL
14.3
- No changes to the data model - Structural update only for new forms and reports
15.0
- The map view for Building (
TC_M_BUILDING) has been extended to include the number of building units (NUMBER_OF_BLDG_UNITS). - A new column “Insertion Group” (
FID_INSERTION_GROUP) has been added to Duct Insertion (TC_SP_DUCT_INSERTION), with a relation to Insertion Group (TC_SP_INSERTION_GROUP). - A new column “Position in Insertion Group” (
INSERTION_GROUP_PLACE_NUMBER) has been added to Duct Insertion (TC_SP_DUCT_INSERTION).
Fiber Optic Data Model
14.1
- Changed the views
TC_M_FO_CLOSUREandTC_M_FO_TERMINATOR- New column
TRUNK_NAME
Contains the name of the cable trunk that is assigned in the closure or the terminator.
- New column
14.2
- New columsn for data source (
FID_TNIM_SOURCE) and source key (TNIM_SOURCE_KEY) in the following tables:TC_FO_CABLE_MODELTC_FO_CLOSURE_MODELTC_FO_CONNECTOR_MODELTC_FO_FIBER_MODELTC_FO_SPLITTER_MODELTC_FO_TERMINATOR_MODELTC_FO_TRAYTC_FO_TRAY_MODELTC_FO_TRUNK
14.3
- Extended the map view for fiber optic cables (
TC_M_FO_CABLE)- New column
FIBER_COUNTcontaining the number of fibers used by a service.
- New column
- Fixed the relation between the fiber optic cable type and the fiber type.
15.0
- A new column “ONT” (
FID_ONT) has been added to Connector (TC_FO_CONNECTOR), linking to ONT (TC_FO_ONT). - New object class “Fiber ONT” (
TC_FO_ONT) added. - New object class “Fiber ONT Model” (
TC_FO_ONT_MODEL) added. - New domain table “Fiber ONT Category” (
TC_FO_ONT_TYPE_TBD) added, with the following predefined values:- 1 – Active (fiber modem)
- 2 – Passive (fiber outlet)
- 99 – Unknown
Telephony Data Model
14.1
- Changed the views
TC_M_TP_CLOSUREandTC_M_TP_TERMINATOR- New column
TRUNK_NAME
Contains the name of the cable trunk that is assigned in the closure or the terminator.
- New column
14.2
- New columsn for data source (
FID_TNIM_SOURCE) and source key (TNIM_SOURCE_KEY) in the following tables:TC_TP_CABLE_MODELTC_TP_CLOSURE_MODELTC_TP_PIN_MODELTC_TP_TERMINATOR_MODELTC_TP_WIRE_MODEL
14.3
- Extended the map view for telephony cables (
TC_M_TP_CABLE)- New column
WIRE_COUNTcontaining the number of wires used by a service.
- New column
- Fixed the relation between the telephony cable type and the wire type.
15.0
- Updated domain entries for the domain table “Frequency” (
TC_TP_FREQUENCY_TBD)- 2 - 0.8kHz
- 3 - 16.8kHz
Redlining Data Model
14.1
Only for PostgreSQL
- New trigger function
tc_f_rl_scan_delete_trigger_functionthat is cleaning up the database in case a scan is removed from the redlining data model. - New trigger
trg_rl_scan_after_deletefor the tabletc_rl_scan
14.2
- New columns in the table service item (
TC_RL_SERVICE_ITEM)- Approval date (
DATE_APPROVAL) - Report date (
DATE_SUBMITTED) - Crew (
NAME_CREW) - Sub-contractor (
NAME_SUBCONTRACTOR)
- Approval date (
- New columns in the table Redlining cable(
TC_RL_CABLE)- Cable reserve start (
CABLE_RESERVE_START) - Cable reserve end (
CABLE_RESERVE_END) - Cable type (
ID_CABLE_TYPE)
- Cable reserve start (
- New columns in the table Redlining scan (
TC_RL_SCAN)- GNSS device (
GNSS_DEVICE) - Positioning quality (
ID_POSITIONING_QUALITY)
- GNSS device (
- Relation of Redlining attribute (
TC_RL_ATTRIBUTE) column feature (FID_FEATURE) extended to target additional feature classes:- Redlining building(
TC_RL_BUILDING) - Redlining building unit(
TC_RL_BUILDING_UNIT) - Redlining cluster (
TC_RL_CLUSTER) - Redlining measurement line (
TC_RL_MEASUREMENT_LINE) - Redlining measurement point (
TC_RL_MEASUREMENT_POINT)
- Redlining building(
- Relation to building (
TC_TG_BUILDING) removed from redning attribute (TC_RL_ATTRIBUTE) - clumn feature (FID_FEATURE). - Relation to Redlining building (
TC_RL_BUILDING) added to Redlining measurement point (TC_RL_MEASUEMENT_POINT) - column feature (FID_FEATURE) - Relation to Redlining building (
TC_RL_BUILDING) added to Redlining segment (TC_RL_SEGMENT) - column feature (FID_FEATURE) - Relation to Redlining building (
TC_RL_BUILDING) added to Redlining terminator (TC_RL_TERMINATOR) - column feature (FID_FEATURE) - New feature classes:
- Redlining building(
TC_RL_BUILDING) - Redlining building unit(
TC_RL_BUILDING_UNIT) - Redlining cluster (
TC_RL_CLUSTER)
- Redlining building(
- New domain table positioning quality (
TC_RL_SCAN_POS_QUALITY_TBD)- 1 - RTK Fix
- 2 - GNSS antenne only
- 3 - Mobiles GPS
- 4 - Manual entry
- 99 - unknown
- Column person (
FID_PERSON) removed from Redlining measurement (TC_RL_MEASUREMENT)
14.3
- New column “Source object” (
SOURCE_OBJECT) in added to Redlining building unit (TC_RL_BUILDING_UNIT).
DocPack
14.1
- New domain table “Plot sequence status” (
TC_PLOT_SEQUENCE_STATUS_TBD) containing the following values:- 1 - Active
- 2 - Inactive
- 3 - Archived
- New column “Status” (
ID_STATUS) in the feature class “Plot sequence” (TC_PLOT_SEQUENCE) with a relation to the domain table “Plot sequence status” (TC_PLOT_SEQUENCE_STATUS_TBD)
14.2
- Added missing caption to plot seqence (
TC_PLOT_SEQUENCE) feature class - No structural changes
Changes to the dialogs since NET 14.0
NET Design
Base Data Model
14.1
- New dialog for the feature class “Surface area” (
TC_PL_SURFACE_AREA)
14.2
- Updated dialog for the feature class “Surface area” (
TC_PL_SURFACE_AREA)- Area value is now rounded to two decimal places
- The selection list for the trench type is now sorted by name
NET Engineering
Base Data Model
14.1
- New API controls
$BTNSHOWALLCABLES,$BTNSHOWALLDUCTS,$BTNSHOWALLSERVICESgot added to the feature class “Segment” (TC_SP_SEGMENT)
14.2
- New Combobox control for data source (
FID_TNIM_SOURCE) and a new text box for the Source ID (TNIM_SOURCE_KEY) got added in the following dialogs:- Cluster (
TC_CLUSTER) - Line (
TC_LINE) - Person (
TC_PERSON) - Point (
TC_POINT) - Cabinet type (
TC_SP_CABINET_MODEL) - Manhole type (
TC_SP_MANHOLE_MODEL) - Marker (
TC_SP_MARKER) - Marker Model (
TC_SP_MARKER_MODEL) - Patch Panel (
TC_SP_PATCH_PANEL) - Patch Panel type (
TC_SP_PATCH_PANEL_MODEL) - Pole Model (
TC_SP_POLE_MODEL) - Rack Panel (
TC_SP_RACK_PANEL) - Rack Panel type (
TC_SP_RACK_PANEL_MODEL) - Segment type (
TC_SP_SEGMENT_MODEL) - Switching point type (
TC_SWITCHING_POINT_MODEL) - Building (
TC_TG_BUILDING) - Building unit (
TC_TG_BUILDING_UNIT)
- Cluster (
- New dialog for the data source (
TNIM_SOURCE)
14.3
- Test button (
$BTNTEST) removed from the dialog for the numbering scheme (TC_NR_SCHEME) - Fixed the layout for the status (
TC_STATUS) dialog
15.0
- Detail form for Number Scheme (Number Scheme Type) –
TC_NR_SCHEME#TC_NR_SCHEME_TYPE- Field
FIELDCOLOR1removed - Field
FIELDCOLOR2removed
- Field
- New form for Insertion Grid (
TC_SP_INSERTION_GRID) - New form for Insertion Grid Type (
TC_SP_INSERTION_GRID_MDL)- New detail form for Insertion Grid Group Template (
TC_SP_INSERTION_GROUP_TBL)
- New detail form for Insertion Grid Group Template (
- New form for Insertion Grid Group (
TC_SP_INSERTION_GROUP) - New form for Insertion Grid Group Template (
TC_SP_INSERTION_GROUP_TBL) - New control in the Status form (
TC_STATUS)- Status Category (
ID_STATUS_CATEGORY) added as a dropdown field
- Status Category (
- New detail form under Building (
TC_TG_BUILDING) for Building Unit (TC_TG_BUILDING_UNIT) –TC_TG_BUILDING#TC_TG_BUILDING_UNIT - The control for Building (
FID_BUILDING) in Building Unit (TC_TG_BUILDING_UNIT) has been changed:
The display now shows the building name. - Several columns have been removed from the Building Unit (
TC_TG_BUILDING_UNIT) form:- Connector (
FID_CONNECTOR) - Source Data Store (
FID_TNIM_SOURCE) - Source ID (
TNIM_SOURCE_KEY)
- Connector (
- New column Name (
NAME) added to Building Unit (TC_TG_BUILDING_UNIT)
Duct Data Model
14.1
- New API controls
$BTNSHOWALLCABLES,$BTNSHOWALLSEGMENTS,$BTNSHOWALLSERVICESgot added to the feature class “Duct” (TC_SP_DUCT)
14.2
- Removed projections from duct (
TC_SP_DUCT) dialog- Show all outer ducts of the filtered ducts
- Show all outer trenches of the filtered ducts
- New Combobox control for data source (
FID_TNIM_SOURCE) and a new text box for the Source ID (TNIM_SOURCE_KEY) got added in the following dialogs:- Duct bundle (
TC_SP_DUCT_BUNDLE) - Duct insertion model (
TC_SP_DUCT_INSERTION_MDL) - Duct type (
TC_SP_DUCT_TYPE) - Fitting type (
TC_SP_FITTING_MODEL)
- Duct bundle (
- Removed projections from trench (
TC_SP_SEGMENT) dialog- Show all inner ducts from the filtered trenches
14.3
- Added projection to the trench (
TC_SP_SEGMENT) dialog - Show all direct inner ducts
15.0
- New controls in the form for Duct Insertion (
TC_SP_DUCT_INSERTION):- Button to highlight connected ducts (
$HIGHLIGHTCONNECTEDDUCT) - Selection field for Insertion Group (
FID_INSERTION_GROUP) - Input field for Position in Insertion Group (
INSERTION_GROUP_PLACE_NUMBER)
- Button to highlight connected ducts (
Fiber Optic Data Model
14.1
- New API controls
$BTNSHOWALLCABLELOOPS,$BTNSHOWALLDUCTS,$BTNSHOWALLSEGMENTSgot added to the feature class “Fo cable” (TC_FO_CABLE) - Decimal places for the column “Attenuation” got increased from two to three for the following feature classes.
- Fo connector data (
TC_FO_CONNECTOR_DATA) - Fo fiber data (
TC_FO_FIBER_DATA) - Fo patch data (
TC_FO_PATCH_DATA) - Fo splice data (
TC_FO_SPLICE_DATA) - Fo splitter data (
TC_FO_SPLITTER_DATA)
- Fo connector data (
- The format of the attenuation in the field “wave length/attenuation” got fixed in the following feature classes.
- Fo connector model (
TC_FO_CONNECTOR_MODEL) - Fo fiber model (
TC_FO_FIBER_MODEL) - Fo splitter model (
TC_FO_SPLITTER_MODEL)
- Fo connector model (
- The projections to the fiber and the fiber optic cable originating from the service (
TC_SERVICE) got fixed. The change only affects SQLite and results in the target dialogs showing the correct number of features.
14.2
- Removed projects from the dialog for the fiber optic cable (
TC_FO_CABLE)- Show all ducts assigned to the current filtered cables
- Show all trenches assigned to the current filtered cables
- New Combobox control for data source (
FID_TNIM_SOURCE) and a new text box for the Source ID (TNIM_SOURCE_KEY) got added in the following dialogs:- Fiber optic cable type (
TC_FO_CABLE_MODEL) - Fiber optic closure type (
TC_FO_CLOSURE_MODEL) - Fiber optic connector type (
TC_FO_CONNECTOR_MODEL) - Fiber type (
TC_FO_FIBER_MODEL) - Fiber optic splitter type (
TC_FO_SPLITTER_MODEL) - Fiber optic terminator type (
TC_FO_TERMINATOR_MODEL) - Fiber optic tray (
TC_FO_TRAY) - Fiber optic tray type (
TC_FO_TRAY_MODEL) - Fiber optic trunk (
TC_FO_TRUNK)
- Fiber optic cable type (
- Removed projects from the dialog for the duct (
TC_SP_DUCT)- Show all cables for the current filtered ducts
- Removed projects from the dialog for the trench (
TC_SP_SEGMENT)- Show all cables for the current filtered trenches
14.3
- Improved selection of the switching point in the dialogs for the fiber optic closure (
TC_FO_CLOSURE) and the fiber optic terminator (TC_FO_TERMINATOR)- FID reference control removed (
$FIDREFERENCE1) - Contents of the selection box for the switching point improved (
FID_SWITCHING_POINT)
- FID reference control removed (
- Fixed the order of the fiber selection list in the fiber optic splice (
TC_FO_SPLICE) dialog
15.0
- New controls in the form for Fiber Connector (
TC_FO_CONNECTOR):- Jump button to ONT (
$APICONTROLCONNECTEDONT) - Reference to ONT (
$REFERENCEONT) - New label for ONT (
$LABEL1)
- Jump button to ONT (
- Label for unit of measure (
$LABEL1) removed from the Connector Data form (TC_FO_CONNECTOR_DATA) - Label for unit of measure (
$LABEL4) removed from the Connector Type form (TC_FO_CONNECTOR_MODEL) - Label for unit of measure (
$LABEL2) removed from the Fiber Data form (TC_FO_FIBER_DATA) - Label for unit of measure (
$LABEL3) removed from the Fiber Type form (TC_FO_FIBER_MODEL) - New form for ONT (
TC_FO_ONT) - New form for ONT Model (
TC_FO_ONT_MODEL)
Telephony Data Model
14.1
- New API controls
$BTNSHOWALLCABLELOOPS,$BTNSHOWALLDUCTS,$BTNSHOWALLSEGMENTSgot added to the feature class “Tp cable” (TC_TP_CABLE) - The projections to the wire and the telephony cable originating from the service (
TC_SERVICE) got fixed. The change only affects SQLite and results in the target dialogs showing the correct number of features.
14.2
- Removed projects from the dialog for the duct (
TC_SP_DUCT)- Show all cables for the current filtered ducts
- Removed projects from the dialog for the trench (
TC_SP_SEGMENT)- Show all cables for the current filtered trenches
- New Combobox control for data source (
FID_TNIM_SOURCE) and a new text box for the Source ID (TNIM_SOURCE_KEY) got added in the following dialogs:- Telephony cable type (
TC_TP_CABLE_MODEL) - Telephony closure type (
TC_TP_CLOSURE_MODEL) - Telephony pin type (
TC_TP_PIN_MODEL) - Telephony terminator type (
TC_TP_TERMINATOR_MODEL) - Wire type (
TC_TP_WIRE_MODEL)
- Telephony cable type (
14.3
- Improved selection of the switching point in the dialogs for the fiber optic closure (
TC_FO_CLOSURE) and the fiber optic terminator (TC_FO_TERMINATOR)- FID reference control removed (
$FIDREFERENCE1) - Contents of the selection box for the switching point improved (
FID_SWITCHING_POINT)
- FID reference control removed (
- Fixed the order of the fiber selection list in the fiber optic splice (
TC_FO_SPLICE) dialog- Improved selection of the switching point in the dialogs for the telephony closure (
TC_TP_CLOSURE) and the telephony terminator (TC_TP_TERMINATOR)- FID reference control removed (
$FIDREFERENCE1) - Contents of the selection box for the switching point improved (
FID_SWITCHING_POINT)
- FID reference control removed (
- Improved selection of the switching point in the dialogs for the telephony closure (
Redlining Data Model
14.2
- Updated the list of target tables for the parent feature in the dialog for the feature class Redlining attribute (
TC_RL_ATTRIBUTE). The changes of the data model are reflected. - New dialog for the Redlining building (
TC_RL_BUILDING) - New dialog for the Redlining building unit (
TC_RL_BUILDING_UNIT) - New dialog for the Redlining cluster (
TC_RL_CLUSTER) - New controls added to the dialog for the Redlining cable (
TC_RL_CABLE)- New selction control for the cable category (
ID_CABLE_TYPE) - New text field for the cable reserve start (
CABLE_RESERVE_START) - New text field for the cable reserve end (
CABLE_RESERVE_END)
- New selction control for the cable category (
- New reference to the Redlining attribute (
TC_RL_ATTRIBUTE) added to the following dialogs- Redlining measurement point (
TC_RL_MEASUREMENT_POINT) - Redlining measurement line (
TC_RL_MEASUREMENT_LINE)
- Redlining measurement point (
- New controls added to the dialog for Redlining scan (
TC_RL_SCAN)- New selection control for the positioning quality (
ID_POSITIONING_QUALITY) - New text field for the GNSS device (
GNSS_DEVICE)
- New selection control for the positioning quality (
- Added Redlining building (
TC_RL_BUILDING) as detail table to the Redlining segment (TC_RL_SEGMENT) - New controls added to the dialog for Redlining service item (
TC_RL_SERVICE_ITEM)- New text field for the approval date (
DATE_APPROVAL) - New text field for the submittet date (
DATE_SUBMITTED) - New text field for the crew (
NAME_CREW) - New text field for the subcontractor (
NAME_SUBCONTRACTOR)
- New text field for the approval date (
- Added Redlining building (
TC_RL_BUILDING) as detail table to the Redlining terminator (TC_RL_TERMINATOR) - Removed control linking the Redlining measurement (
TC_RL_MEASUREMENT) to the person (FID_PERSON) from the dialog. - New text field synchronization date (
DATE_SYNC) added to the Redlining measurement (TC_RL_MEASUREMENT) dialog.
14.3
- New text field for the source object (
SOURCE_OBJECT) added to the Redlining building unit (TC_RL_BUILDING_UNIT)
DocPack
14.1
- New control “Status” for the column
ID_STATUSadded to the dialog for the feature class “plot sequence” (TC_PLOT_SEQUENCE)
Changes of the reports since NET 14.0
NET Engineering
Base Data Model
14.3
- An error breaking the fault report in Autodesk Map 3D 2025 got fixed
15.0
- New report function (
GETRECORDEXISTSCONDITION) added to all reports. The function checks if the report filter contains any data.
Duct Data Model
15.0
- Added a new function to support dynamic line breaks to the duct end overview
Fiber Optic Data Model
14.3
- The installation location is now correctly displayed in the report for the trays in closures
- The alignment of the text inside the columns of the splice overview got fixed
15.0
- The reports “Fiber Connector Occupancy at Termination” and “Fiber Connector Occupancy (Connected) at Termination” have been revised.
In both cases, the “Number of Patchings in Termination” has been corrected. - The reports “Fiber Splice Closure Occupancy Plan” and “Fiber Splice Closure Occupancy Plan – Landscape” have been improved:
- Cells now expand dynamically based on their content.
- A new column has been added with information about the splitter.
Telephony Data Model
14.1
- The reports for the network overviews got fixed to allow the creation of an aggregated report, created by the DocPack.