Connection editor from NET 11

Connections at the fiber/wire layer are created with the connection editor. Depending on the point from which the connection editor was opened, different connection options result.

The connection editor can be opened in the FO/TP Terminator, FO/TP Closure or Switching point form and from the NET tab.

FO

FO Terminator FO closure
Verbindungseditor_Start_Abschluss_LWL_engl.png Verbindungseditor_Start_Muffe_LWL_engl.png


TP

TP Terminator TP Closure
Verbindungseditor_Start_Abschluss_FM_engl.png Verbindungseditor_Start_Muffe_FM_engl.png


General

Switching point Work order
Verbindungseditor_Start_SP_engl.png Verbindungseditor_Start_Reg_NET_engl.png


Points between which connections are possible:

Point Point Connection
FO Terminator FO Closure Patch Fiber
FO Terminator FO Terminator Patch/Switching fiber
FO Closure FO Closure Patch Fiber
TP Terminator TP Terminator Patch


If you open the connection editor from the NET tab, there are no objects in the preview yet. The points in which connections are to be created must be selected in the graphic Verbindungseditor_Button_Auswahl aus Grafik.png. Depending on the connection editor started, only points that belong to the FO Network or TP Network can be selected.

Verbindungseditor_Start_Reg_NET_leer_engl.png

If you open the connection editor from the switching point, the points assigned to the switching point are in the preview or can be selected from the list. In this case, it is automatically checked whether the corresponding points (FO or TP) are assigned to the switching point.

Example: FO

Verbindungseditor_Start_SP_gefüllt_SF_engl.png

If you open the connection editor from the terminator or the closure, only the incoming/outgoing cables are listed and no other devices.

Verbindungseditor_Start_Muffe_gefüllt_F-F_engl.png

Verbindungseditor_Button_Auswahl aus Grafik.png Another point can be selected in the graphic
Verbindungseditor_Button_Highlight.png The selected point is highlighted in the graphic
Verbindungseditor_Button_Konfiguration_engl.png The options for displaying the columns can be set
Verbindungseditor_Button_Hilfe.png NET help can be opened

 

Options

Clicking on the gear-wheel icon opens the dialog for the options:

Verbindungseditor_Konfiguration_engl.png

The columns to be displayed are defined for all types of objects that can be connected.

Verbindungseditor_Button_Konfiguration_Neu_engl.png Add new column
Verbindungseditor_Button_Konfiguration_Pfeil oben_engl.png Move up/forward in sequence
Verbindungseditor_Button_Konfiguration_Pfeil unten_engl.png Move down/backward in the sequence
Verbindungseditor_Button_Konfiguration_ändern_engl.png Modify column definition
Verbindungseditor_Button_Konfiguration_löschen_engl.png Delete column definition
Verbindungseditor_Button_Konfiguration_speichern_engl.png Save and export the options as a JSON file
Verbindungseditor_Button_Konfiguration_exportieren_engl.png Import options from a JSON file


If new columns are to be added, the following dialog opens:

Verbindungseditor_Spaltenkonfiguration_engl.png

Name The name of the column can be specified.
Description A description for the column can be entered.
Source Verbindungseditor_Spaltenkonfiguration_Quelle_Auswahlliste_engl.png An attribute, SQL command or auxiliary column can be selected as the source.
Depending on which source has been selected, the selection options under “Details” will change.
Details
Attribute An attribute of the feature class can be specified.
Type The attribute type can be selected.


Example: Fiber—Attribute

Attribute Type
Verbindungseditor_Spaltenkonfiguration_Quelle_Attribut_Auswahlliste_engl.png Verbindungseditor_Spaltenkonfiguration_Quelle_Typ_Auswahlliste_engl.png


Example: Fiber—SQL

SQL Type
Verbindungseditor_Spaltenkonfiguration_Faser_Quelle SQL.png Verbindungseditor_Spaltenkonfiguration_Quelle_SQL_Typ_Auswahlliste_engl.png


Example: Fiber—Auxiliary column

Type Type
Verbindungseditor_Spaltenkonfiguration_Faser_Quelle Zusatzspalte_Typ I_engl.png Verbindungseditor_Spaltenkonfiguration_Faser_Quelle Zusatzspalte_Typ II_engl.png

 

Actions

The drop-down list of actions includes all possibilities for connections and their disconnections depending on the objects selected. In addition, trays can be modified and new ones added under Edit.

Verbindungseditor_Aktionen_Auswahlliste_engl.png

Connecting

FO Terminator with connectors and splitters FO Closure with splitter Switching point with FO nodes
Verbindungseditor_Aktionen_Verbinden_LWL-Muffe_engl.png Verbindungseditor_Aktionen_Verbinden_LWL-SP_engl.png
TP Terminator with pins TP Closure Switching point with TP nodes
Verbindungseditor_Aktionen_Verbinden_FM-Abschluss_engl.png Verbindungseditor_Aktionen_Verbinden_FM-Muffe_engl.png Verbindungseditor_Aktionen_Verbinden_FM-SP_engl.png


Depending on the selected connection action, the left, center and right panes are adjusted and the corresponding objects are loaded in the preview.

Verbindungseditor_Aktionen_Verbinden_LWL-Muffe_Faser-Splitter_engl.png

Cables and splitters can be selected from the drop-down lists. Fibers and splitter paths are then selected. In the center, you specify the tray in which the splices are to be placed.

Filtering elements

A variety of filters can be applied in any of the columns.

The following text-filtering characters can be used for a filter in Names.

Verbindungseditor_Filter_alle Kabel_Filter_Tooltipp_engl.png

For example, for a filter in numbers, specific quantities of elements can be selected with >, < and =.

Filtering for a specific text in the name with “All cables” selected:

Verbindungseditor_Filter_alle Kabel_Filter_Kabelname_engl.png

Filtering for all fibers 1 to 4, i.e., less than 5:

Verbindungseditor_Filter_alle Kabel_Filter_Fasernummer_engl.png

Parts of the result:

Verbindungseditor_Filter_alle Kabel_Filter_Ergebnis_engl.png

Disconnecting

FO Terminator with connectors and splitters FO Closure with splitter Switching point with FO nodes
Verbindungseditor_Aktionen_Trennen_Muffe_LWL_engl.png not possible
TP Terminator with pins TP Closure Switching point with TP nodes
Verbindungseditor_Aktionen_Trennen_Abschluss_FM_engl.png Verbindungseditor_Aktionen_Trennen_Muffe_FM_engl.png not possible


Connections can only be disconnected within a point. Patches or patch fibers between two points can be retrieved, filtered and deleted from the respective terminators/closures.

Verbindungseditor_Aktionen_Trennen_LWL-Muffe_Faser-Faser_engl.png

If the connected cables are indicated in “Disconnect fibers”, the connected fibers are likewise selected with the choice of the corresponding fibers.

Editing

FO Terminator with connectors and splitters FO Closure with splitter Switching point with FO nodes
Verbindungseditor_Aktionen_Bearbeiten_LWL-Abschluss_engl.png Verbindungseditor_Aktionen_Bearbeiten_LWL-Muffe_engl.png not possible
TP Terminator with pins TP Closure Switching point with TP nodes
Verbindungseditor_Aktionen_Bearbeiten_FM-Abschluss_engl.png not possible not possible


Existing trays can be modified, new trays can be added or existing trays can be deleted.

Unbenannt.pngVerbindungseditor_Aktionen_Bearbeiten_Kassetten_engl.png

The available trays are displayed in the left pane. If you select one of these, the type, closure side, name and number can be modified in the central pane.

Existing trays can be deleted or new ones added via the context menu in the left pane.

Verbindungseditor_Aktionen_Bearbeiten_Muffe_LWL_Kassetten_Kontextmenü_engl.png

If new trays have been added, they can be then be modified.

Verbindungseditor_Aktionen_Bearbeiten_Kassetten_ändern_engl.png

Connectors/pins can also be deleted in the FO/TP terminators.

Verbindungseditor_Aktionen_Bearbeiten_Kupplungen_löschen_engl.png

With “Create action”, the changes are transferred to the action list and with “Run”, the changes are applied.

A wide variety of actions can be created successively—even in different points—and only run at a later point in time. However, the connection editor must not be closed until then.

If there are still open actions, the following query appears:

LWL-Verbindungseditor_geöffnet_Meldung_nicht ausgeführte Änderungen_engl.png

You can discard the changes or cancel closing the connection editor.