After the preprocessing, all trench routes relevant for the planning are managed in the “Possible Trench” feature class.
This means only those records that are included in this feature class will also be taken into account in the planning.
During the preprocessing, the “Possible Trench” are generated from the “Street Center Lines”, taking into account the street width. In addition, the “Possible Trench” are given a “Trench Class” attribute. This defines whether it is a lead-in, a street trench or a street crossing, etc.
With each preprocessing, all records in the “Possible Trench” object class are deleted and created anew. For this reason, changes in street routes must not be made to the “Possible Trench” but to “Street Center Lines”.
Opening the form
The following options are available for opening the form:
- In the Industry Model Explorer by right-clicking on Feature class > Show form
additionally, for feature classes with geometry,
- by double-clicking on the geometry in the graphic window
- by single-clicking on the geometry in the graphic window and display the form by pressing the button in the Industry Model Explorer
The form consists of a “Possible Trench” main form and the detailed form for “Planning Attribute Value”.
Form details
“Possible Trench” are given the following attributes by default:
Main form | |
Attribute / Form entry / Button |
Meaning |
Postcode |
ZIP code |
City |
Street location |
Street |
Street name |
Abbreviation |
Street abbreviation |
Group ID (Comsof optimizer only) |
Trenches with the same ID ≥ 0 belong to an intersection. |
Is Private (atesio optimizer only) |
YES/NO. Classification of the record |
Is Included |
Determines whether the object will be considered in the planning. |
Is Locked |
This attribute only applies to records that use the “Lead-in” trench class and is only supported by Comsof Fiber Designer. |
Maximum amount of ducts (Comsof optimizer only) |
Limits the shared use of the possible trench to the defined number of ducts. Caution: The value applies per layer. Under certain circumstances, this restriction is ignored if the network could not otherwise be calculated. |
Maximum amount of cables (Comsof optimizer only) |
Limits the shared use of the possible trench to the defined number of cables.Caution: The value applies per layer. Under certain circumstances, this restriction is ignored if the network could not otherwise be calculated. |
Maximum amount of fibers (Comsof optimizer only) |
Limits the shared use of the possible trench to the defined number of fibers. Caution: The value applies per network layer. Under certain circumstances, this restriction is ignored if the network could not otherwise be calculated. |
Street Center Line |
Display of the FID of the street center line on which the possible trench is based. |
Defines the class of the trench: Street trench, street crossing, drop trench, etc. |
|
Defines the surface / construction method of roads/streets; dedicated costs can be stored in the rules for the calculation for each type. |
|
Jump button to the result: Used trenches that use this record. | |
Excluded Layers |
In order to prohibit the use of the possible trenches for certain network layers, the corresponding check box must be activated. |
Duct Type Constraint (Comsof optimizer only) |
This attribute is used to restrict the use of ducts for the respective record to certain duct types. This attribute is populated from the street center lines during the preprocessing. |
Detailed form |
|
Attribute / Form entry / Button |
Meaning |
Value |
User-defined attribute value |
Attribute |
User-defined attribute name |
Feature |
FID of the record to which the planning attribute value belongs |
CAUTION
Planning attribute values of possible trenches are assigned to the corresponding NET Engineering trenches when creating the detailed planning.