Settings for the Export— Cables

 

mceclip0.png

Other cable > for project-specific customer adjustments

Placeholders

Explanation

{AGG_ID}

 

This placeholder is replaced by the aggregation ID of the higher layer point. 

{UPSTREAM_ID}

 

This placeholder is replaced by the full {UPSTREAM_ID} of the higher layer point of the cable.

{CITY}

 

This placeholder is replaced by the city of the higher layer point (input). 

{POSTCODE}

This placeholder is replaced by the ZIP code of the higher layer point (input). 

{STREET}

This placeholder is replaced by the street of the higher layer point (input).

{HOUSE_NR}

           

This placeholder is replaced by the house number of the higher layer point (input). 

{DUCT_IDX}

 

This placeholder is replaced by the index of the multi-duct bundle in which the cable is located. If the cable is not located in a duct, the index is set to 0. The duct at the higher layer point determines the numbering. 

{MICRODUCT_NR}

 

This placeholder is replaced by the number of the microduct in which the cable was placed. If the cable is in a conventional duct, the index of the conventional duct at the start point is used.  

{TREE_POS}

This placeholder is replaced by the tree-position ID. This is only the case if it is a shared cable that supplies several subordinate layer points. The ID consists of lowercase letters that identify the respective branch.

{ID}

 

This placeholder is replaced by the full ID of the cable. It consists of the upstream ID of the cable followed by the duct index, microduct index and the tree-position ID. 

{TARGET_AGG_ID}

 

This placeholder is replaced by the aggregation ID of the subordinate layer point that is connected by the cable. It is the downstream aggregation ID.

In the case of a shared cable, TARGET_AGG_ID is the respective end of the shared cable.

{GLOBAL_SEQ}

 

This placeholder is replaced by a global counter that counts across the cables of all network layers.

{LAYER_SEQ}

 

This placeholder is replaced by a counter that applies to all cables of the same network layer.

{LAYER_POINT_SEQ}

 

This placeholder is replaced by a counter for each higher layer distribution point that is individual for each cable.

{END_SEC}

This is a unique name for each cable that connects a specific device. 

{START-NAME}

This is the device name at the start point of the cable. 

{END-NAME}

This is the device name at the end point of the cable.

{START_AGG_ID}

This is the device aggregation ID at the start point of the cable. 

{END_AGG_ID}

This is the device aggregation ID at the end point of the cable. In the case of a shared cable, END_AGG_ID is the respective end of the complete cable.

TYPE_NAME

Identifier of the cable