Other cable > for project-specific customer adjustments
Placeholders |
Explanation |
{AGG_ID}
|
This placeholder is replaced by the aggregation ID of the higher layer point. |
{UPSTREAM_ID}
|
This placeholder is replaced by the full {UPSTREAM_ID} of the higher layer point of the cable. |
{CITY}
|
This placeholder is replaced by the city of the higher layer point (input). |
{POSTCODE} |
This placeholder is replaced by the ZIP code of the higher layer point (input). |
{STREET} |
This placeholder is replaced by the street of the higher layer point (input). |
{HOUSE_NR}
|
This placeholder is replaced by the house number of the higher layer point (input). |
{DUCT_IDX}
|
This placeholder is replaced by the index of the multi-duct bundle in which the cable is located. If the cable is not located in a duct, the index is set to 0. The duct at the higher layer point determines the numbering. |
{MICRODUCT_NR}
|
This placeholder is replaced by the number of the microduct in which the cable was placed. If the cable is in a conventional duct, the index of the conventional duct at the start point is used. |
{TREE_POS} |
This placeholder is replaced by the tree-position ID. This is only the case if it is a shared cable that supplies several subordinate layer points. The ID consists of lowercase letters that identify the respective branch. |
{ID}
|
This placeholder is replaced by the full ID of the cable. It consists of the upstream ID of the cable followed by the duct index, microduct index and the tree-position ID. |
{TARGET_AGG_ID}
|
This placeholder is replaced by the aggregation ID of the subordinate layer point that is connected by the cable. It is the downstream aggregation ID. In the case of a shared cable, TARGET_AGG_ID is the respective end of the shared cable. |
{GLOBAL_SEQ}
|
This placeholder is replaced by a global counter that counts across the cables of all network layers. |
{LAYER_SEQ}
|
This placeholder is replaced by a counter that applies to all cables of the same network layer. |
{LAYER_POINT_SEQ}
|
This placeholder is replaced by a counter for each higher layer distribution point that is individual for each cable. |
{END_SEC} |
This is a unique name for each cable that connects a specific device. |
{START-NAME} |
This is the device name at the start point of the cable. |
{END-NAME} |
This is the device name at the end point of the cable. |
{START_AGG_ID} |
This is the device aggregation ID at the start point of the cable. |
{END_AGG_ID} |
This is the device aggregation ID at the end point of the cable. In the case of a shared cable, END_AGG_ID is the respective end of the complete cable. |
TYPE_NAME |
Identifier of the cable |